Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: TECTA AMERICA SOUTHEAST LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TECTA AMERICA SOUTHEAST LLC in 1904 W. VINE ST., KISSIMMEE, FL 34741 (NAICS 238160). OSHA activity number 339612046.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tecta America Southeast LLC for free Get an email when a new federal OSHA severe-injury report for Tecta America Southeast LLC is published. One employer, no account, unsubscribe in one click.
Site address
1904 W. VINE ST.
City
KISSIMMEE
State
FL
ZIP
34741
Mailing
588 MONROE ROAD, SANFORD, FL 32771
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
Private (A)

3 citations on file for this inspection.

1926.453 B02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 14, 2014
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1926.453(b)(2)(iv): Employee(s) working in an aerial lift were not standing firmly on the floor of the basket:  a. On or about 03/05/2014, at the job site - an employee operating an aerial lift was exposed to a 28 feet 6 inches fall hazard, in that, he climbed over the guard rails to go into the roof.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $3500

1926.453 B02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 14, 2014
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:Note:  As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system.  The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated  a. On or about 03/05/2014, at the job site - the use of personal fall protection was not enforced while operating an aerial lift to install metal roofing panels, exposing the worker to a 28 feet 6 inches fall hazard.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $3500

1926.760 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 14, 2014
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems.  a. On or about 03/05/2014, at the job site - the use of personal fall protection was not enforced while installing metal roofing panels on a 6:12 sloped roof, exposing the worker to a 28 feet 6 inches fall hazard.
Recent events (2)
  • · I (S) $2940
  • · Z (S) $4900

View Tecta America Southeast LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339612046.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.