Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: MAJESTIC SOLUTIONS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MAJESTIC SOLUTIONS, INC. in 241 PRODUCTION AVE, MADISON, AL 35758 (NAICS 337124). OSHA activity number 339612137.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Majestic Solutions, INC. for free Get an email when a new federal OSHA severe-injury report for Majestic Solutions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
241 PRODUCTION AVE
City
MADISON
State
AL
ZIP
35758
Mailing
241 PRODUCTION AVE, MADISON, AL 35758
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337124
Employees
6
Ownership type
Private (A)

7 citations on file for this inspection.

1910.23 E01

Serious Gravity 1 1 instance 4 exposed
Issued
Mar 19, 2014
Abate by
Mar 27, 2014
Penalty
Initial $1,020 · Current $612 Reduced
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level:  (a) On or about 3/5/14 - at the stairway from the office area to the shop, the railing did not have an intermediate rail.
Recent events (2)
  • · I (S) $612
  • · Z (S) $1020

1910.212 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 19, 2014
Abate by
Mar 27, 2014
Penalty
Initial $2,040 · Current $1,224 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) On or about 3/5/14 - in the Shop area, the blade on the horizontal band saw was not guarded.
Recent events (2)
  • · I (S) $1224
  • · Z (S) $2040

1910.304 G05

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 19, 2014
Abate by
Mar 25, 2014
Penalty
Initial $2,040 · Current $1,224 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  (a) On or about 3/5/14 - in the Shop Area, the grounding pin was missing on the plug for the horizontal band saw.
Recent events (2)
  • · I (S) $1224
  • · Z (S) $2040

1910.305 G02 III

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 19, 2014
Abate by
Mar 25, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  (a) On or about 3/5/14 - in the Shop Area, the strain relief on the plug for the horizontal band saw was broken.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.106 E02 II

Other-than-serious 1 instance 4 exposed
Issued
Mar 19, 2014
Abate by
Mar 25, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(2)(ii): Flammable or combustible liquids were not stored in tanks or closed containers:  (a) On or about 3/5/14 - at the outside flammable storage building, two 5-gallon containers of Xylene were not closed.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.253 B04 III

Other-than-serious 2 instances 4 exposed
Issued
Mar 19, 2014
Abate by
Mar 25, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  (a) On or about 3/5/14 - at the loading dock, an oxygen cylinder was stored within 3-feet of an acetylene cylinder and three liquid pertroleum gas cyclinders.  (b) On or about 3/5/14 - at the shop area, oxygen and acetylene cylinders were stored together on a mobile cart.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 H03

Other-than-serious 1 instance 4 exposed
Issued
Mar 19, 2014
Abate by
Apr 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3): The employee training did not include the requirements of 29 CFR 1910.1200(h)(3)(i) through (h)(3)(iv):  (a) On or about 3/5/14 - at 241 Production Ave., Madison, AL, the employer had not provided employee training to meet the requirements of the new Hazard Communication Standard which requires training such as but not limited to label elements, how labels might be used in the workplace, safety data sheet (SDS) format, and how labels and SDS are related.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339612137.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.