ELK GROVE VILLAGE, IL —
OSHA Inspection: SCHIELE GRAPHICS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SCHIELE GRAPHICS, INC. in 1880 BUSSE ROAD, ELK GROVE VILLAGE, IL 60007 (NAICS 323113). OSHA activity number 339613010.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SCHIELE GRAPHICS, INC.
- Site address
- 1880 BUSSE ROAD
- City
- ELK GROVE VILLAGE
- State
- IL
- ZIP
- 60007
- Mailing
- 1880 BUSSE ROAD, ELK GROVE VILLAGE, IL 60007
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323113
- Employees
- 86
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.178 L04 III
- Issued
- May 2, 2014
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator(s) performance was not conducted at least once every three years: a) The employer did not conduct an evaluation of each employee that operate the powered industrial truck at least once every three years of the last training.
Recent events (2)
- — I (S) $1190
- — Z (S) $2380
1910.213 H01
- Issued
- May 2, 2014
- Abate by
- May 29, 2014
- Penalty
- Initial $2,975 · Current $1,488 Reduced
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade were not guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with the stock being cut to give maximum protection possible for the operation being performed: a) Back Storage Room - The Craftsman radial arm saw did not have the lower portion of the blade guarded by a device that will automatically adjust itself to the thickness of the stock and remain in contact with the stock.
Recent events (2)
- — I (S) $1487.5
- — Z (S) $2975
1910.219 D01
- Issued
- May 2, 2014
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulleys, with parts of which are seven (7) feet or less from the floor or working platform, were not guarded in accordance with the standards specified in paragraphs (m) and (o) of this section: a) Tabbing Department - The Precision Drill Master model #B, serial #85B305, Tabbing Machine had the pulley not completely guarded to prevent contact with the moving parts.
Recent events (2)
- — I (S) $1190
- — Z (S) $2380
1910.219 E03 I
- Issued
- May 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts were not enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section: a) Tabbing Department - The Precision Drill Master model #B, serial #85B305, Tabbing Machine had the vertical belt not completely guarded to prevent contact with the moving parts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- May 2, 2014
- Abate by
- May 29, 2014
- Penalty
- Initial $1,785 · Current $893 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled equipment were not used or installed in accordance with any instructions included in the listing or labeling: a) Tabbing Department - A power strip used to power equipment in the area was not listed or labeled or installed in accordance with any instructions.
Recent events (2)
- — I (S) $892.5
- — Z (S) $1785
1910.303 G01 II
- Issued
- May 2, 2014
- Abate by
- May 29, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): Working space about electrical equipment rated 600 volts, nominal, or was used for storage: a) Printing Department Alongside East Wall - A rolling storage unit placed directly in front of an electrical cabinet and other disconnect switches that power the printing machines. b) Printing Department Alongside East Wall - A box filled with paper and an office cabinet with a lap top directly in front of a disconnect switch to power the printing presses. c) Printing Department Alongside East Wall - A desk and other materials stored directly in front of a disconnect switch to power the printing presses.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Schiele Graphics, INC.