Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: PEP BOYS #797

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PEP BOYS #797 in 13729 RESEARCH BLVD, AUSTIN, TX 78750 (NAICS 811111). OSHA activity number 339614661.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PEP Boys #797 for free Get an email when a new federal OSHA severe-injury report for PEP Boys #797 is published. One employer, no account, unsubscribe in one click.
Establishment
PEP BOYS #797
Site address
13729 RESEARCH BLVD
City
AUSTIN
State
TX
ZIP
78750
Mailing
13729 RESEARCH BLVD, AUSTIN, TX 78750
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
18
Ownership type
Private (A)

5 citations on file for this inspection.

1910.37 B07

Serious Gravity 1 1 instance 10 exposed
Issued
Jun 6, 2014
Abate by
Jun 25, 2014
Penalty
Initial $3,000 · Current $1,800 Reduced
29 CFR 1910.37(b)(7): Each exit sign did not have the word "Exit" in plainly leligible letters not less that six inches (15.2 cm) high, with the principal strokes of the letters in the word "Exit" not less than three fourths of an inch (1.9 cm) wide:  On or about March 4, 2014, and at times prior thereto, the exit discharge door near Bay #10 did not have an adequate "EXIT" sign in that the lettering was not six inches high or more on the sign taped to the door, exposing employees to the hazards of fire in the event of an emergency.
Recent events (2)
  • · I (S) $1800
  • · Z (S) $3000

1910.145 F03

Serious Gravity 5 2 instances 5 exposed
Issued
Jun 6, 2014
Abate by
Jun 25, 2014
Penalty
Initial $4,000 · Current $2,400 Reduced
29 CFR 1910.145(f)(3): Tags were not used as a means to prevent accidental injury or illness to employees who were exposed to hazardous or potentially hazardous conditions, equipment or operations which were out of the ordinary, unexpected or not readily apparent:  a)  On or about, March 4, 2014, and at times prior thereto, the in ground vehicle lift in bay #7 was not tagged out at the controls to indicate that it was not fully operable.   b)  On or about, March 4, 2014, and at times prior thereto, two brake lathes in the store room were not tagged out to indicate they were defective or not in service.
Recent events (2)
  • · I (S) $2400
  • · Z (S) $4000

1910.212 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 6, 2014
Abate by
Jun 25, 2014
Penalty
Initial $4,000 · Current $2,400 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a)  On or about, March 4, 2014, and at times prior thereto, an AMMCO Disc/Drum Brake Lathe for cutting or grinding was not equipped with a guard to protect the operator against the hazards of being struck by flying chips and debris.
Recent events (2)
  • · I (S) $2400
  • · Z (S) $4000

1910.36 D01

Repeat Gravity 1 1 instance 7 exposed
Issued
Jun 6, 2014
Abate by
Jun 25, 2014
Penalty
Initial $6,000 · Current $3,600 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  On or about March 4, 2014, and at times prior thereto, the only egress door for the store room was not able to be unlocked from the inside, exposing employees to the hazards of fire in the event of an emergency.  Pep Boys was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.36(d)(1), which was contained in OSHA inspection number 314229097, Citation number 1, Item number 1, and was affirmed as a final order on December 1, 2010, with respect to a workplace located at 3700 Edgemont Ave., Brookhaven, PA 19015.
Recent events (2)
  • · I (R) $3600
  • · Z (R) $6000

1910.305 G02 III

Repeat Gravity 5 1 instance 5 exposed
Issued
Jun 6, 2014
Abate by
Jun 25, 2014
Penalty
Initial $8,000 · Current $4,800 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  Bay #10:  On or about March 4, 2014, and at times prior thereto, there was no strain relief on the pendant electrical cord used by employees to energize portable tools and equipment, exposing employees to the hazards of electrical shock.  Pep Boys was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.305(g)(2)(iii), which was contained in OSHA inspection number 914663, Citation number 1, Item number 2, and was affirmed as a final order on August 1, 2013, with respect to a workplace located at 5134 S Wadsworth Blvd, CO 80123.
Recent events (2)
  • · I (R) $4800
  • · Z (R) $8000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339614661.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.