Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FRANCO S MASONRY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FRANCO S MASONRY, INC. in 1741 GRATZ STREET, PHILADELPHIA, PA 19121 (NAICS 238140). OSHA activity number 339614885.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Franco S Masonry, INC. — free Get an email when a new federal OSHA severe-injury report for Franco S Masonry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1741 GRATZ STREET
City
PHILADELPHIA
State
PA
ZIP
19121
Mailing
93 MEADOW LANE, NORRISTOWN, PA 19403
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
A

7 citations on file for this inspection.

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 16, 2014
Abate by
Apr 23, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.        a)  1741 Gratz Street, Philadelphia, PA- Employees were exposed to fall hazards while working installing house wrap and stucco wire at heights up to 30 feet above a lower level without any form of fall protection.  Observed on or about January 17, 2014.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.451 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 16, 2014
Abate by
Apr 23, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(1):  Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports:   a)  1741 Gratz Street, Philadelphia, PA- Employees were exposed to fall hazards while installing house wrap and stucco wire at heights up to 30 feet above the lower level in that the scaffold levels were not fully planked. Working levels consisted of one, two or three nominal 2x10 planks.  Observed on or about January 17, 2014.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 16, 2014
Abate by
Apr 23, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide:     a)  1741 Gratz Street, Philadelphia, PA- Employees were exposed to fall hazards of approximately 13 feet while using the single plank ramp between the scaffold on the side of the house and the scaffold on the back of the house.  Observed on or about January 17, 2014.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.451 E05 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 16, 2014
Abate by
Apr 23, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(5)(i): Ramps and walkways 6 feet (1.8 m) or more above lower levels did not have guardrail systems that comply with subpart M of this part (Fall Protection):   a)  1741 Gratz Street, Philadelphia, PA- Employees were exposed to fall hazards of approximately 13 feet while using the single plank ramp between the scaffold on the side of the house and the scaffold on the back of the house that was not equipped with any guardrail system.  Observed on or about January 17, 2014.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 16, 2014
Abate by
Apr 23, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph.     a)  1741 Gratz Street, Philadelphia, PA- Employees were exposed to fall hazards while installing house wrap and stucco wire from a scaffold that was not guyed, tied, or braced at heights up to 30 feet or a (6:1) height to base width ratio.  Observed on or about January 17, 2014.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 16, 2014
Abate by
Apr 23, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(1): A means of access for scaffold platforms more than 2 feet (0.6 m) above or below a point of access, such as portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used.   a)  1741 Gratz Street, Philadelphia, PA- Employees accessed the working levels of a steel frame mason's walk through scaffold built six frames high by climbing the frames.  There was no ladder present and these frames are not suitable for climbing. Observed on or about January 17, 2014.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F07

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 16, 2014
Abate by
Sep 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.     a)  1741 Gratz Street, Philadelphia, PA- Employees erected a steel frame mason's walk through scaffold six frames high and began work installing house wrap and stucco wire at heights up to 30 feet above a lower level from the incomplete scaffold.  There was no one competent in scaffold erection present directing the work. Observed on or about January 17, 2014.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339614885.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.