Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: HARBOR ENTERPRISES LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HARBOR ENTERPRISES LLC. in 1207 SUNSET DRIVE, THOMASVILLE, GA 31792 (NAICS 332312). OSHA activity number 339616096.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Harbor Enterprises LLC. for free Get an email when a new federal OSHA severe-injury report for Harbor Enterprises LLC. is published. One employer, no account, unsubscribe in one click.
Site address
1207 SUNSET DRIVE
City
THOMASVILLE
State
GA
ZIP
31792
Mailing
1207 SUNSET DRIVE, THOMASVILLE, GA 31792
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
19
Ownership type
Private (A)

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 5 exposed
Issued
May 2, 2014
Abate by
May 29, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by and crush-by hazards.   a) Plant production area  On or about and at time prior to March 4, 2014, the employer did not ensure employees were trained on the safe operation and use of below the hook lifting devices such as, but not limited to Industrial Strength Magnetic Lifts (Earth Magnets). The lifting magnets load rating, testing data and manufacturers safe and proper use was not known, exposing employees to crushing and struck-by hazards.      ABATEMENT CERTIFICATION AND DOCUMENTATION ARE REQUIRED
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.106 D07 I

Serious Gravity 5 1 instance 3 exposed
Issued
May 2, 2014
Penalty
Initial $2,040 · Current $1,224 Reduced
29 CFR 1910.106(d)(7)(i): Suitable fire control devices, such as small hose or portable fire extinguishers, were not available at locations where flammable liquids were stored:  a) Outside diesel refueling area-On or about and at times prior to March 4, 2014, the employer failed to provide a readily accessible fire control device such as, but not limited to a portable fire extinguisher at the 150-gallon, single wall diesel tank, exposing employees to a life safety hazard.
Recent events (2)
  • · I (S) $1224
  • · Z (S) $2040

1910.157 C01

Serious Gravity 5 1 instance 3 exposed
Issued
May 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a)  Caterpillar Forklift, Model DP45K1, S/N AT19C80593 - On or about and at times prior to March 4, 2014, the employer provided a fire extinguisher that was mounted with duct tape making the fire extinguisher not inaccessible and ready for use, exposing the employee to a life safety hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.157 C04

Serious Gravity 5 1 instance 1 exposed
Issued
May 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:  a)  John Deere Forklift Model 386E RT S/N T04361X844779  - On or about and at times prior to March 4, 2014, a fire extinguisher mounted and ready for use was fully discharged, exposing employees to life safety hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.157 E01

Serious Gravity 5 2 instances 2 exposed
Issued
May 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(1): The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace:  a)  John Deere Forklift Model 386E RT S/N T04361X844779  - On or about and at times prior to March 4, 2014, the fire extinguisher mounted and ready for use was fully discharged, and had not been inspected as, exposing employees to life safety hazards.                                       b)  Caterpillar Forklift, Model DP45K1, S/N AT19C80593 - On or about and at times prior to March 4, 2014, the employer provided a fire extinguisher that was mounted with duct tape making the fire extinguisher inaccessible  use, and had not been inspected as required, exposing the employee to a life safety hazard.                                       ABATEMENT CERTIFICATION IS NOT REQUIRED
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 A04

Serious Gravity 5 1 instance 3 exposed
Issued
May 2, 2014
Abate by
May 29, 2014
Penalty
Initial $1,700 · Current $1,020 Reduced
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval:  a)  Forklifts used throughout facility - On or about and at times prior to March 4, 2014,  forklifts were purchased with pre-existing holes cut near the fork tips,  and the employer used a trailer ball hitch attached to the forks to push and pull trailers used to transport storm shelter shelters.  The employer used the modified application without pre-approval from the forklift manufacturers, exposing employees to tipping, ejection, and struck-by hazards.     ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • · I (S) $1020
  • · Z (S) $1700

1910.145 C03

Other-than-serious 1 instance 3 exposed
Issued
May 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.145(c)(3): Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s):  a)  Outside at the 150 gallon above ground diesel tank - On or about and at time prior to March 4, 2014, warning signs such as, but not limited to, No Smoking, were not posted near a portable 150-gallon single wall diesel tank, exposing employees to life safety hazard.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339616096.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.