COLUMBUS, OH —
OSHA Inspection: UNIVERSAL FABRICATING & CONST SERVICES DBA UNIFACS
Follow-up inspection · Health discipline
At a glance
On , OSHA opened a follow-up health inspection of UNIVERSAL FABRICATING & CONST SERVICES DBA UNIFACS in 1241 MCKINLEY AVENUE, COLUMBUS, OH 43222 (NAICS 236220). OSHA activity number 339617243.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNIVERSAL FABRICATING & CONST SERVICES DBA UNIFACS
- Site address
- 1241 MCKINLEY AVENUE
- City
- COLUMBUS
- State
- OH
- ZIP
- 43222
- Mailing
- 1241 MCKINLEY AVENUE, COLUMBUS, OH 43222
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 42
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.179 L03 III D
- Issued
- Apr 8, 2014
- Abate by
- Apr 18, 2014
- Penalty
- Initial $1,785 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.179(l)(3)(iii)(d): Pendant control stations shall be kept clean and function labels kept legible. a. In the assembly bay area, the controls on the assembly bay crane were covered with paint and were not clean and legible.
Recent events (2)
- — I (S) $1249.5
- — Z (S) $1785
1904.32 B03
- Issued
- Apr 8, 2014
- Abate by
- Apr 18, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.32(b)(3): How do I certify the annual summary? A company executive must certify that he or she has examined the OSHA 300 Log and that he or she reasonably believes, based on his or her knowledge of the process by which the information was recorded, that the annual summary is correct and complete. a. On or about February 27, the highest ranking official at the company did not certify the OSHA Form 300A for the calendar year 2013.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Universal Fabricating & Const Services DBA Unifacs
View Universal Fabricating & Const Services DBA Unifacs's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339617243.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.