Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: AIRPORT ELECTRIC, CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AIRPORT ELECTRIC, CO. in 801 S. WOLCOTT, CHICAGO, IL 60612 (NAICS 238210). OSHA activity number 339617649.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Airport Electric, CO. for free Get an email when a new federal OSHA severe-injury report for Airport Electric, CO. is published. One employer, no account, unsubscribe in one click.
Site address
801 S. WOLCOTT
City
CHICAGO
State
IL
ZIP
60612
Mailing
6342 S. CENTRAL AVE., CHICAGO, IL 60638
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
8
Ownership type
Private (A)

2 citations on file for this inspection.

1926.403 I02 I

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 18, 2014
Abate by
Apr 30, 2014
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1926.403(i)(2)(i): Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures:  a. On or about March 7, 2014 - at the above addressed jobsite, employees conducting construction and demolition operations on the third floor were exposed to electrical hazards due to a live electrical panel box without a cover.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2000

1926.405 A02 II I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 18, 2014
Abate by
Apr 30, 2014
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables shall be protected from damage. Sharp corners and projections shall be avoided. Flexible cords and cables may pass through doorways or other pinch points, if protection is provided to avoid damage.  a. On or about March 7, 2014 - at the above addressed jobsite, employees conducting construction and demolition operations on the second, third and fourth floors were exposed to electrical hazards due to live electrical parts not being protected from damage.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339617649.