TARRYTOWN, NY ·
OSHA Inspection: FRANK'S HOME IMPROVEMENTS & SIDING CO., INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FRANK'S HOME IMPROVEMENTS & SIDING CO., INC. in 46 SUNNYSIDE AVE., TARRYTOWN, NY 10591 (NAICS 236118). OSHA activity number 339617706.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FRANK'S HOME IMPROVEMENTS & SIDING CO., INC.
- Site address
- 46 SUNNYSIDE AVE.
- City
- TARRYTOWN
- State
- NY
- ZIP
- 10591
- Mailing
- 361 N. BROADWAY, SLEEPY HOLLOW, NY 10591
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 7
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.21 B02
- Issued
- Mar 14, 2014
- Abate by
- May 7, 2014
- Penalty
- Initial $1,600 · Current $1,040 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury: location: entire site on or about: 3/6/14 a) Employees, engaged in residential remodeling work, were exposed to several hazards, including scaffold and electrical hazards. The employees were not provided with safety training.
Recent events (2)
- · I (S) $1040
- · Z (S) $1600
1926.454 A
- Issued
- Mar 14, 2014
- Abate by
- Apr 16, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: location: entire site on or about: 3/6/14 a) Employees, engaged in residential remodeling work, were exposed to several scaffold hazards. The employees were not provided with scaffold safety training.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.404 B01 I
- Issued
- Mar 14, 2014
- Abate by
- Mar 24, 2014
- Penalty
- Initial $2,000 · Current $1,300 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): General. The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors: location: entire site on or about: 3/6/14 a) Employees were using electrical equipment, including a Makita saw, while engaged in residential remodeling work. The employees were not provided with GFCI protection or an assured equipment grounding conductor program.
Recent events (2)
- · I (S) $1300
- · Z (S) $2000
1926.451 B02 I
- Issued
- Mar 14, 2014
- Penalty
- Initial $1,600 · Current $1,040 Reduced
General-duty citation text
29 CFR 1926.451(b)(2)(i): Each ladder jack scaffold, top plate bracket scaffold, roof bracket scaffold, and pump jack scaffold was not at least 12 inches (30 cm) wide: location: front of house on or about: 3/6/14 a) An employee was working from a pump jack/ladder jack scaffold. The platform consisted of only one 8' 3/4" wide plank.
Recent events (2)
- · I (S) $1040
- · Z (S) $1600
1926.451 B05 II
- Issued
- Mar 14, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(5)(ii): Each platform greater than 10 feet in length extended over its support more than 18 inches (46 cm), and it was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end: location: South side of house on or about: 3/6/14 a) An employee was working from a pump jack scaffold. The platform extended several feet beyond the support.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 F03
- Issued
- Mar 14, 2014
- Penalty
- Initial $1,600 · Current $1,040 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: location: entire site on or about: 3/6/14 a) An employee was working from a combination of pump jack and ladder jack scaffolds, that were connected to each other. The scaffolds were not inspected for visable defects.
Recent events (2)
- · I (S) $1040
- · Z (S) $1600
1926.451 F07
- Issued
- Mar 14, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities were not performed only by experienced and trained employees selected for such work by the competent person: location: entire site on or about: 3/6/14 a) An employee was working from a combination of pump jack and ladder jack scaffolding, that were connected to each other. The scaffolds were not erected under the supervision and direction of a competent person qualified in scaffold erection.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.452 J02
- Issued
- Mar 14, 2014
- Penalty
- Initial $1,200 · Current $780 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: location: south side of house on or about: 3/6/14 a) An employee was working from a pump jack scaffold. The pump jack scaffold was not braced at the bottom of the poles.
Recent events (2)
- · I (S) $780
- · Z (S) $1200
More inspections at Frank'S Home Improvements & Siding CO., INC.
View Frank'S Home Improvements & Siding CO., INC.'s full OSHA safety record →