PITTSBURGH, PA ·
OSHA Inspection: TOTAL SYSTEMS TECHNOLOGY, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of TOTAL SYSTEMS TECHNOLOGY, INC. in 65 TERENCE DRIVE, PITTSBURGH, PA 15236 (NAICS 325211). OSHA activity number 339618308.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TOTAL SYSTEMS TECHNOLOGY, INC.
- Site address
- 65 TERENCE DRIVE
- City
- PITTSBURGH
- State
- PA
- ZIP
- 15236
- Mailing
- 65 TERENCE DRIVE, PITTSBURGH, PA 15236
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325211
- Employees
- 13
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.22 C
- Issued
- Jul 15, 2014
- Penalty
- Initial $1,600 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.22(c): Covers and/or guardrails were not provided to protect personnel from the hazards of open pits, tanks, vats, ditches, etc.: a) 2nd Floor storage room, on or about March 7, 2014 - A mechanical fan was installed in an opening in the ceiling between the storage room and the undercoating garage. The open hole was not guarded to prevent employees from fall hazards while replacing air filter.
Recent events (2)
- · I (S) $1100
- · Z (S) $1600
1910.1200 E01
- Issued
- Jul 15, 2014
- Abate by
- Jul 23, 2014
- Penalty
- Initial $1,200 · Current $700 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employer did not develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met: a) Worksite, on or about March 7, 2014 - The employer did not develop a written hazard communication program. Employees used the following solvents during the undercoating process: Rust Remedy II, clear rustproofing which contained calcium carbonate and petrolatum; Auto Undercoat, which contained petroleum asphalt and mineral spirits; and rubberized undercoating.
Recent events (2)
- · I (S) $700
- · Z (S) $1200
1910.1200 H01
- Issued
- Jul 15, 2014
- Abate by
- Jul 23, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard: a) Worksite, on or about March, 7, 2014 - Employees were not provided with effective information and training on the hazardous chemicals at the worksite. Employees used following solvents during the undercoating process: Rust Remedy II, clear rustproofing which contained calcium carbonate and petrolatum; Auto Undercoat, which contained petroleum asphalt and mineral spirits; and rubberized undercoating.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 C
- Issued
- Jul 15, 2014
- Abate by
- Aug 2, 2014
- Penalty
- Initial $0 · Current $0
0290
General-duty citation text
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: a) Worksite, on or about April 17, 2014 - The employer did not develop and implement a written respiratory program. Employees are required to use a tight-fitting half-face respirator while spray painting rustproofing undercoating. Employees used North 7000 Series equipped with organic cartridges with back up N95 filters.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.134 H01
- Issued
- Jul 15, 2014
- Abate by
- Aug 2, 2014
- Penalty
- Initial $0 · Current $0
0290
General-duty citation text
29 CFR 1910.134(h)(1): The employer did not ensure that respirators are cleaned and disinfected using the procedures in Appendix B-2 of this section, or procedures recommended by the respirator manufacturer, provided that such procedures are of equivalent effectiveness: a) Worksite, on or about April 17, 2014 - Tight-fitting half-face respirators were not clean or disinfected after they were used during spray painting rustproofing undercoating operations. Employees were required to use a North 7000 Series respirator equipped with organic cartridges with back up N95 filters.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.134 K05
- Issued
- Jul 15, 2014
- Abate by
- Aug 2, 2014
- Penalty
- Initial $0 · Current $0
0290
General-duty citation text
29 CFR 1910.134(k)(5): Respirator retraining was not administered annually: a) Worksite, on or about April 17, 2014 - Employees are required to use a tight-fitting half-face respirator while spray painting rustproofing undercoating. Employees were not provided annual respirator training in 2013, or up-to-date 2014.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Total Systems Technology, INC.