WINNETKA, IL —
OSHA Inspection: STONEGATE MASONRY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STONEGATE MASONRY, INC. in 925 PINE TREE, WINNETKA, IL 60093 (NAICS 238140). OSHA activity number 339622920.
Where did this inspection happen?
- Establishment
- STONEGATE MASONRY, INC.
- Site address
- 925 PINE TREE
- City
- WINNETKA
- State
- IL
- ZIP
- 60093
- Mailing
- 310 CHERRYWOOD ROAD, BUFFALO GROVE, IL 60089
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $15400.00 · Current $15400.00
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) Employees were exposed to the hazard of falling from working levels at elevations of approximately 30 feet while working from scaffolding platforms that were not fully planked. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — A (W) $15400
- — I (W) $6000
- — Z (W) $15400
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a) Employees were exposed to the hazard of falling from elevation of approximately 30 feet while working from scaffolding without the benefit of fall protection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — A (W) $0
- — I (W) $0
- — Z (W) $0
1926.602 D
- Issued
- Abate by
- Penalty
- Initial $6160.00 · Current $6160.00
General-duty citation text
29 CFR 1926.602(d): Note: The requirements applicable to construction work under paragraph (d) of this section are identical to those set forth at paragraph (l) of 29 CFR 1910.178. 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) The employer permitted the operation of an all-terrain forklift without ensuring the employee was competent to operate the equipment safely, as demonstrated by successful completion of forklift training and evaluation. Stonegate Masonry, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.602(d) which was contained in OSHA inspection number 315512103, citation 1, item 3, and was affirmed as a final order on July 1, 2011, with respect to a worksite located at 411 Sheridan, Winnetka, Illinois. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — A (R) $6160
- — I (R) $4000
- — Z (R) $6160
More inspections at STONEGATE MASONRY, INC.
WINNETKA, IL—2011-05-19 00:00:00
STONEGATE MASONRY, INC.
WINNETKA, IL—2011-02-18 00:00:00
STONEGATE MASONRY, INC.
View STONEGATE MASONRY, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
LOMPOC, CA—2026-07-10
UNKNOWN EMPLOYER
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
CINCINNATI, OH—2026-07-09
ALL AMERICAN CONCRETE LLC
NEW YORK, NY—2026-07-08
JEY CONSTRUCTIONS WORKS CORP
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR