BOOTHBAY HARBOR, ME ·
OSHA Inspection: ARTHUR D. HENRY CRANE SERVICE
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ARTHUR D. HENRY CRANE SERVICE in 185 TOWNSEND AVE., BOOTHBAY HARBOR, ME 04538 (NAICS 238990). OSHA activity number 339624744.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARTHUR D. HENRY CRANE SERVICE
- Site address
- 185 TOWNSEND AVE.
- City
- BOOTHBAY HARBOR
- State
- ME
- ZIP
- 04538
- Mailing
- 34 NEWMAN LANE, THOMASTON, ME 04861
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 4
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.1404 Q01
- Issued
- Mar 13, 2014
- Abate by
- Mar 19, 2014
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1926.1404(q)(1): The outriggers or stabilizers must be either fully extended or, if manufacturer procedures permit, deployed as specified in the load chart. Jobsite: Employee exposed to boom truck tipping hazards for not fully extend drivers side rear outrigger during lifting operations.
Recent events (2)
- · I (S) $1960
- · Z (S) $2800
1926.1404 Q04
- Issued
- Mar 13, 2014
- Abate by
- Apr 29, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1404(q)(4): Each outrigger or stabilizer must be visible to the operator or to a signal person during extension and setting. Jobsite: Employee had an obstruction (HVAC unit) blocking his view of the drivers side rear outrigger.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1412 F07
- Issued
- Mar 13, 2014
- Abate by
- Apr 29, 2014
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1926.1412(f)(7): Documentation of annual/comprehensive inspection. The following information must be documented, maintained, and retained for a minimum of 12 months, by the employer that conducts the inspection: Jobsite: No documentation could be provided on the Terex TC-4792 boom truck.
Recent events (2)
- · I (S) $1960
- · Z (S) $2800
More inspections in this industry (NAICS 238990)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339624744.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.