Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: CLEBURNE CLEANERS INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CLEBURNE CLEANERS INC. in 119 PRAIRIE AVE, CLEBURNE, TX 76031 (NAICS 812320). OSHA activity number 339626426.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cleburne Cleaners INC. for free Get an email when a new federal OSHA severe-injury report for Cleburne Cleaners INC. is published. One employer, no account, unsubscribe in one click.
Site address
119 PRAIRIE AVE
City
CLEBURNE
State
TX
ZIP
76031
Mailing
119 PRAIRIE AVE, CLEBURNE, TX 76031
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812320
Employees
28
Ownership type
A

8 citations on file for this inspection.

1910.22 A02

Serious Gravity 5 1 instance 15 exposed
Issued
Jul 17, 2014
Abate by
Aug 14, 2014
Penalty
Initial $3,150 · Current $2,000 Reduced
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:    On or about March 12, 2014, and times prior thereto, in the laundry and dry cleaning plant, the employer did not ensure the floors located by electrical panels and a Rema Dri-Vac wer maintained in a dry condition exposing employees to electrical shock and slip and fall hazards.
Recent events (2)
  • · I (S) $2000
  • · Z (S) $3150

1910.22 A03

Serious Gravity 1 1 instance 15 exposed
Issued
Jul 17, 2014
Abate by
Aug 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(3): Every floor, working place, and passageway was not kept free from protruding nails, splinters, holes, or loose boards:  On or about March 12, 2014, and times prior thereto, in the laundry area the concrete floor was breaking up creating uneven surface exposing employees to trip and fall hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.37 B02

Serious Gravity 5 4 instances 15 exposed
Issued
Jul 17, 2014
Abate by
Aug 14, 2014
Penalty
Initial $3,213 · Current $1,200 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":    On or about March 12, 2104, and times prior thereto, the employer did not ensure that each exit was marked:    1. The front door exit of the plant located on the north side of the building.    2. The side door exit of the plant located on the west side of the building.    3. The back door exit of the plant located on the south side of the building.      4. The lobby exit doors.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $3213

1910.305 G01 IV A

Serious Gravity 5 1 instance 15 exposed
Issued
Jul 17, 2014
Abate by
Aug 14, 2014
Penalty
Initial $2,142 · Current $1,200 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    On or about March 12, 2014, and times prior thereto, in the boiler room, the employer used an extension cord in lieu of permanent wiring exposing employees to electrical hazards.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2142

1910.305 G01 IV C

Serious Gravity 5 2 instances 2 exposed
Issued
Jul 17, 2014
Abate by
Aug 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were used where run through doorways, windows, or similar openings:  On or about March 12, 2014, and times prior thereto, the employer used extension cords routed thru the boiler room door to an air compressor located outside the boiler room to supply electrical power to heat lamps.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G01 IV D

Serious Gravity 5 2 instances 2 exposed
Issued
Jul 17, 2014
Abate by
Aug 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were used where attached to building surfaces:  On or about March 12, 2014, and times prior thereto, the employer used extension cords attached to the building walls of the boiler room to supply electrical power to heat lamps.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 E01

Serious Gravity 10 1 instance 15 exposed
Issued
Jul 17, 2014
Abate by
Aug 14, 2014
Penalty
Initial $4,410 · Current $1,730 Reduced
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):    On or about March 12, 2014, and at times prior thereto, the employer did not have a written hazard communication program exposing employees to inhalation, eye, skin, hazards and illnesses.
Recent events (2)
  • · I (S) $1730
  • · Z (S) $4410

1904.1 A02

Other-than-serious 3 instances 15 exposed
Issued
Jul 17, 2014
Abate by
Aug 14, 2014
Penalty
Initial $630 · Current $630
29 CFR 1904.1(a)(2): The company has more than ten (10) employees at any time during the last calendar year and did not keep OSHA injury and illness records.  On or about March 12, 2014, and times prior thereto, the employer did not maintain OSHA 300 Logs and Records.
Recent events (2)
  • · I (O) $630
  • · Z (O) $630

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339626426.