Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: BULLDOG FENCE OF FLORIDA, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BULLDOG FENCE OF FLORIDA, LLC in 240 BAHAMA LANE, PALM BEACH, FL 33480 (NAICS 238990). OSHA activity number 339628455.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bulldog Fence of Florida, LLC for free Get an email when a new federal OSHA severe-injury report for Bulldog Fence of Florida, LLC is published. One employer, no account, unsubscribe in one click.
Site address
240 BAHAMA LANE
City
PALM BEACH
State
FL
ZIP
33480
Mailing
120 COMMERCE ROAD SUITE D, BOYNTON BEACH, FL 33426
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
17
Ownership type
Private (A)

2 citations on file for this inspection.

1926.600 A06 I

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 2, 2014
Penalty
Initial $4,900 · Current $4,000 Reduced
29 CFR 1926.600(a)(6)(i): 29 CFR 1926.600(a)(6)(i):  For lines rated 50kV or below, a minimum of 10 feet was not maintained between the energized line and the equipment:    a. On or about March 6, 2014, at the above addressed jobsite, employees were exposed to an electric shock while assisting a Caterpillar backhoe loader operator with the installation of metal fence poles and attaching/installing chain link fencing to metal fence poles along a golf course perimeter in close proximity to overhead high voltage electrical power lines that were not de-energized, grounded or guarded.
Recent events (3)
  • · R (S) $4000
  • · C (S) $4900
  • · Z (S) $4900

1926.21 B02

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Sep 2, 2014
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:  a. On or about March 6, 2014, at the above addressed jobsite, employees who were not instructed in the recognition and avoidance of electric shock were assisting a Caterpillar backhoe loader operator with the installation of metal fence poles and attaching/installing chain link fencing to metal fence poles along a golf course perimeter in close proximity to overhead electrical power lines.
Recent events (3)
  • · R (S) $0
  • · C (S) $4900
  • · Z (S) $4900

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339628455.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.