Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALABAMA'S BEST FABRICATORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALABAMA'S BEST FABRICATORS, INC. in 1595 RED HOLLOW ROAD, BIRMINGHAM, AL 35215 (NAICS 332710). OSHA activity number 339628547.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alabama'S Best Fabricators, INC. — free Get an email when a new federal OSHA severe-injury report for Alabama'S Best Fabricators, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1595 RED HOLLOW ROAD
City
BIRMINGHAM
State
AL
ZIP
35215
Mailing
P.O. BOX 708, PINSON, AL 35126
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
11
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 30, 2014
Abate by
May 27, 2014
Penalty
Initial $1,700 · Current $1,020 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) On or about 03/12/2014 - Shop area, lockout / tagout procedures were not developed, documented, nor utilized to control hazardous energy for employees changing dies on a Pullmax hydraulic press brake machine.
Recent events (2)
  • — I (S) $1020
  • — Z (S) $1700

1910.178 L01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 30, 2014
Abate by
Jun 17, 2014
Penalty
Initial $1,700 · Current $1,020 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  (a) On or about 03/12/2014 - Facility, the employer did not ensure that practical training and an evaluation of the operator's performance was successfully completed as part of forklift training.
Recent events (2)
  • — I (S) $1020
  • — Z (S) $1700

1910.304 F01 IV

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 30, 2014
Abate by
May 12, 2014
Penalty
Initial $1,020 · Current $612 Reduced
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel:  (a) On or about 03/12/2014 - Shop area, a 480-volt circuit breaker panel was blocked by material.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

View Alabama'S Best Fabricators, INC.'s full OSHA safety record →