BIDDEFORD, ME ·
OSHA Inspection: T & D TIMBER PRODUCTS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of T & D TIMBER PRODUCTS in 26 POMERLEAU STREET, BIDDEFORD, ME 04005 (NAICS 321999). OSHA activity number 339630360.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- T & D TIMBER PRODUCTS
- Site address
- 26 POMERLEAU STREET
- City
- BIDDEFORD
- State
- ME
- ZIP
- 04005
- Mailing
- 26 POMERLEAU STREET, BIDDEFORD, ME 04005
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 15
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.36 D01
- Issued
- Mar 18, 2014
- Abate by
- Mar 26, 2014
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: At the Facility - The exit door on the back side of the drilling station was locked, preventing employees from opening it from the inside.
Recent events (2)
- · I (O) $0
- · Z (S) $1600
1910.157 C04
- Issued
- Mar 18, 2014
- Abate by
- Mar 26, 2014
- Penalty
- Initial $1,600 · Current $1,120 Reduced
General-duty citation text
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition and they were not kept in their designated place at all times except during use: At the Facility - The portable fire extinguisher located on the back wall near the drilling station was not charged nor was it mounted.
Recent events (2)
- · I (S) $1120
- · Z (S) $1600
1910.157 E02
- Issued
- Mar 18, 2014
- Abate by
- Mar 26, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: At the Facility - The employer did not visually inspect portable fire extinguishers on a monthly basis.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.219 D01
- Issued
- Mar 18, 2014
- Abate by
- Apr 4, 2014
- Penalty
- Initial $1,600 · Current $1,120 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): Outside - The drive belt/pulley assembly for the live deck was not guarded.
Recent events (2)
- · I (S) $1120
- · Z (S) $1600
1910.219 F03
- Issued
- Mar 18, 2014
- Abate by
- Apr 4, 2014
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: Outside - The chain and sprocket drive for the advancement of the live deck was not guarded.
Recent events (2)
- · I (S) $0
- · Z (S) $1600
1904.29 A
- Issued
- Mar 18, 2014
- Abate by
- Mar 26, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.29(a): The employer did not use an OSHA 300, 301 and 300A Form or equivalent: At the Facility - The employer did not maintain OSHA 300 logs.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.37 B06
- Issued
- Mar 18, 2014
- Abate by
- Apr 4, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: At the Facility - The exit signs were not illuminated nor were they of a distinctive color.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.212 A01
- Issued
- Mar 18, 2014
- Abate by
- Apr 4, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Production Area - Machine guarding was not provided to protect the operator from the rotating part of the drill.
Recent events (2)
- · I (O) $0
- · Z (O) $0