Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TEKKOTE CORP.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TEKKOTE CORP. in 1100 SLOCUM AVE., RIDGEFIELD, NJ 07657 (NAICS 322221). OSHA activity number 339632101.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tekkote Corp. — free Get an email when a new federal OSHA severe-injury report for Tekkote Corp. is published. One employer, no account, unsubscribe in one click.
Establishment
TEKKOTE CORP.
Site address
1100 SLOCUM AVE.
City
RIDGEFIELD
State
NJ
ZIP
07657
Mailing
580 WILLOW TREE ROAD, LEONIA, NJ 07605
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322221
Employees
37
Ownership type
A

2 citations on file for this inspection.

1910.147 C02 II

Serious Gravity 10 2 instances 4 exposed
Issued
Jul 17, 2014
Abate by
Jul 29, 2014
Penalty
Initial $5,390 · Current $2,680 Reduced
29 CFR 1910.147(c)(2)(ii): If an energy isolating device is capable of being locked out, the employer's energy control program under paragraph (c)(1) of this section shall utilize lockout, unless the employer can demonstrate that the utilization of a tagout system will provide full employee protection as set forth in paragraph (c)(3) of this section.    Location: Manufacturing floor    a) Employees troubleshooting a web-break on Coater #64 were exposed to amputation hazards while operating the Coater without using lock out procedures; on or about 02/11/14.    b) Employee performing routine maintenance on Coater #64 was exposed to an amputation hazard while not using lock out procedures; on or about 02/21/14.
Recent events (3)
  • — F (S) $2680
  • — C (S) $5390
  • — Z (S) $5390

1910.147 C06 II

Other-than-serious 1 instance 4 exposed
Issued
Jul 17, 2014
Abate by
Jul 29, 2014
Penalty
Initial $5,390 · Current $0 Reduced
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.    a) Manufacturing floor- Employer did not maintain a log of periodic inspections of energy control procedures, such as but not limited to, coater machines; on or 2/11/14.
Recent events (3)
  • — R (O) $0
  • — C (S) $5390
  • — Z (S) $5390

View Tekkote Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339632101.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.