BIRMINGHAM, AL ·
OSHA Inspection: MAGNA COSMA INTERNATIONAL DBA KAMTEK, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MAGNA COSMA INTERNATIONAL DBA KAMTEK, INC. in 1595 STERILITE DRIVE, BIRMINGHAM, AL 35215 (NAICS 336370). OSHA activity number 339632309.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAGNA COSMA INTERNATIONAL DBA KAMTEK, INC.
- Site address
- 1595 STERILITE DRIVE
- City
- BIRMINGHAM
- State
- AL
- ZIP
- 35215
- Mailing
- 1595 STERILITE DRIVE, BIRMINGHAM, AL 35215
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336370
- Employees
- 650
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.212 A01
- Issued
- Aug 5, 2014
- Abate by
- Aug 29, 2014
- Penalty
- Initial $7,000 · Current $4,200 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On or about 03/11/14 - CNC Milling Area, interlocks were not provided for the doors on the CNC Milling machine. (b) On or about 03/11/14 - Tool Room, a guard was not provided for the rotating spindle on the OKK milling machine. (c) On or about 03/11/14 - Tool Room, a guard was not provided for the rotating spindle on the Maximart/Bridgeport milling machine. (d) On or about 03/11/14 - Tool Room, a guard was not provided for the rotating spindle on the Bridgeport #17 milling machine.
Recent events (2)
- · I (S) $4200
- · Z (S) $7000
1910.23 A09
- Issued
- Aug 5, 2014
- Abate by
- Aug 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(a)(9): Every floor hole into which persons cannot accidentally walk (on account of fixed machinery, equipment, or walls) were not protected by a cover that leaves no openings more than one inch wide: (a) On or about 03/11/14 - Mezzanine over fender line, a cover was not provided for the floor hole around the cooling water tanks.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.132 D02
- Issued
- Aug 5, 2014
- Abate by
- Aug 15, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: (a) On or about 03/11/14 - Facility, the employer did not certify that the required workplace hazard assessment had been performed.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.147 C06 II
- Issued
- Aug 5, 2014
- Abate by
- Aug 15, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: (a) On or about 03/11/14 - Facility, the employer did not certify that an annual inspection of the energy control procedures had been performed.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.305 B01 II
- Issued
- Aug 5, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) On or about 03/11/14 - Transfer Press, the 110 volt electrical box for the conveyor belt had a knockout missing. (b) On or about 03/11/14 - Transfer Press, the 110 volt electrical control box for the conveyor belt had two unused openings.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Magna Cosma International DBA Kamtek, INC.
View Magna Cosma International DBA Kamtek, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336370)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339632309.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.