BALDWIN, FL —
OSHA Inspection: C AND C POWERLINE, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of C AND C POWERLINE, INC. in 16770 REBAR ROAD, BALDWIN, FL 32234 (NAICS 238210). OSHA activity number 339632895.
Where did this inspection happen?
- Establishment
- C AND C POWERLINE, INC.
- Site address
- 16770 REBAR ROAD
- City
- BALDWIN
- State
- FL
- ZIP
- 32234
- Mailing
- 12035 PALM LAKE DRIVE, JACKSONVILLE, FL 32218
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 76
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.269 A02 III
- Issued
- Penalty
- Initial $4900.00 · Current $4200.00 Reduced
General-duty citation text
29 CFR 1910.269(a)(2)(iii): The employer did not determine through regular supervision and through inspections conducted on at least an annual basis, that each employee was complying with the safety related work practices required by this section: a. On or about March 14, 2014, the employer did not determine through regular supervision and through inspections, conducted on at least an annual basis, that each employee was complying with the safety related work practices when three employees cut into an energized 23kV primary high voltage power line and resulted in an electrical arc flash that injured two employees.
Recent events (3)
- — F (S) $4200
- — C (S) $4900
- — Z (S) $4900
1910.269 M03 V
- Issued
- Penalty
- Initial $4900.00 · Current $4200.00 Reduced
General-duty citation text
29 CFR 1910.269(m)(3)(v): After the applicable requirements in paragraphs (m)(3)(i) through (m)(3)(iv) of 29 CFR 1910.269(m)(3) have been followed and the employee in charge of the work has been given a clearance by the system operator, the lines and equipment to be worked were not tested to ensure that they are de-energized: a. On or about March 14, 2014, the employee in charge did not test an exposed underground 23kV primary high voltage power line to ensure that it was de-energized prior to working on the line and resulted in an electrical arc flash that injured two employees.
Recent events (3)
- — F (S) $4200
- — C (S) $4900
- — Z (S) $4900
More inspections at C AND C POWERLINE, INC.
EASTPOINT, FL—2006-04-03 00:00:00
C AND C POWERLINE, INC.
JACKSONVILLE, FL—2003-09-11 00:00:00
C AND C POWERLINE, INC.
JACKSONVILLE, FL—2000-07-13 00:00:00
C AND C POWERLINE, INC.
JACKSONVILLE, FL—2000-07-05 00:00:00
C AND C POWERLINE, INC.
JACKSONVILLE, FL—2000-05-11 00:00:00
C AND C POWERLINE, INC.
View C AND C POWERLINE, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
PARKVILLE, MD—2026-07-15
THE POWER SOURCE, INC.
SOUTH BARRINGTON, IL—2026-07-15
EDGE ELECTRICAL SYSTEMS, LLC
LAYTON, UT—2026-07-14
LYNN WOODWARD ELECTRIC LLC
BRIDGEPORT, WV—2026-07-14
INFINITY ELECTRIC & SERVICE COMPANY, LLC
ANNAPOLIS, MD—2026-07-14
J.M. MULLEN ELECTRICAL SERVICES, INC.
More inspections in FL
MARIANNA, FL—2026-07-16
BRANNON BROTHERS CONSTRUCTION, LLC
LAKELAND, FL—2026-07-16
SOUTHERN MILLING & LUMBER, INC.
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
LAKELAND, FL—2026-07-16
ELIJAH WHOLESALE, LLC.
TAMPA, FL—2026-07-16
VALENCIA WHOLESALE, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339632895.