OSHA Inspection: UNIVERSAL DRYWALL LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of UNIVERSAL DRYWALL LLC in 155 6TH STREET, CHELSEA, MA 02150 (NAICS 238310). OSHA activity number 339632945.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Universal Drywall LLC — free Get an email when a new federal OSHA severe-injury report for Universal Drywall LLC is published. One employer, no account, unsubscribe in one click.
Site address
155 6TH STREET
City
CHELSEA
State
MA
ZIP
02150
Mailing
320 ROCKINGHAM ROAD UNIT 8, AUBURN, NH 03032
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
40
Ownership type
A

6 citations on file for this inspection.

1910.134 A02

Deleted Serious Gravity 5 1 instance 20 exposed
Issued
Apr 8, 2014
Abate by
May 23, 2014
Penalty
Initial $3,080 · Current $0 Reduced
29 CFR 1910.134(a)(2): The employer did not establish and maintain a respiratory protection program which included the requirements outlined in 29 CFR 1910.134(c): As indicated in the note under 29 CFR 1926.103 the requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.134 of this chapter.     (a)    Location: 155 6th Street, Chelsea, MA    On or about 3/14/14, the employer did not establish and implement a respiratory program for employees required to wear respirators.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3080

1910.178 L04 III

Deleted Serious Gravity 5 1 instance 22 exposed
Issued
Apr 8, 2014
Abate by
May 23, 2014
Penalty
Initial $3,850 · Current $0 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operators performance was not conducted at least once every 3 years:  As indicated in the note under 29 CFR 1926.602(d) the requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.178(l) of this chapter.    (a)    Location: 155 6th Street, Chelsea, MA   On or about 3/14/14, an employee operating an all-terrain fork lift was not reevaluated in the operation of the fork lift at least every three years.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3850

1926.405 A02 II I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 8, 2014
Penalty
Initial $3,080 · Current $2,000 Reduced
29 CFR 1926.405(a)(2)(ii)(I): Protection was not provided to avoid damage to flexible cords and cables used for temporary wiring which passed through doorways or other pinch points:     (a)    Location: 155 6th Street, Chelsea, MA   On or about 3/14/14, an extension cord used to heat the engine on an all-terrain fork lift was not protected from being pinched when passing through a doorway.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3080

1926.405 G02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 8, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:       (a)    Location: 155 6th Street, Chelsea, MA  On or about 3/14/14, employees were not protected from electric shock and burns  from an electrical cord that had no strain relief.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.416 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 8, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:       (a)    Location: 155 6th Street, Chelsea, MA  On or about 3/14/14, employees were not protected from electric shock and burns from an electrical cord that was frayed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.503 B01

Other-than-serious 1 instance 2 exposed
Issued
Apr 8, 2014
Abate by
May 23, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.  (a)    Location: 155 6th Street, Chelsea, MA  On or about 3/14/14, the employer did not provide a written fall protection training certification record for employees who may be exposed to fall hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Universal Drywall LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339632945.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.