NORWOOD, MA ·
OSHA Inspection: MANUFACTURING RESOURCE GROUP, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MANUFACTURING RESOURCE GROUP, INC. in 930 WASHINGTON STREET, NORWOOD, MA 02062 (NAICS 335931). OSHA activity number 339634321.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MANUFACTURING RESOURCE GROUP, INC.
- Site address
- 930 WASHINGTON STREET
- City
- NORWOOD
- State
- MA
- ZIP
- 02062
- Mailing
- 930 WASHINGTON STREET, NORWOOD, MA 02062
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335931
- Employees
- 88
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.212 A03 II
- Issued
- Mar 19, 2014
- Abate by
- May 7, 2014
- Penalty
- Initial $4,200 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Tubing Cutting Area: Schleuniger OC3950 tubing cutter was not adequately guarded to prevent employees from being in the danger zone resulting in an employee suffering a partial finger amputation
Recent events (2)
- · I (S) $3150
- · Z (S) $4200
1910.303 B02
- Issued
- Mar 19, 2014
- Abate by
- Jul 31, 2014
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Assembly area: Four outlet knock out type boxes were used as hanging pendants exposing employees to fire and electricial shock hazards.
Recent events (2)
- · I (S) $1050
- · Z (S) $2100
1910.305 G02 III
- Issued
- Mar 19, 2014
- Abate by
- Jul 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) Assembly Area: Flexible cords running from the ceiling were stretched and pulled in such a manner as to put strain on the joints and terminals exposing employees to fire and electrical shock hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0