OSHA Inspection: MANUFACTURING RESOURCE GROUP, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MANUFACTURING RESOURCE GROUP, INC. in 930 WASHINGTON STREET, NORWOOD, MA 02062 (NAICS 335931). OSHA activity number 339634321.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Manufacturing Resource Group, INC. for free Get an email when a new federal OSHA severe-injury report for Manufacturing Resource Group, INC. is published. One employer, no account, unsubscribe in one click.
Site address
930 WASHINGTON STREET
City
NORWOOD
State
MA
ZIP
02062
Mailing
930 WASHINGTON STREET, NORWOOD, MA 02062
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335931
Employees
88
Ownership type
Private (A)

3 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 19, 2014
Abate by
May 7, 2014
Penalty
Initial $4,200 · Current $3,150 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):     (a) Tubing Cutting Area: Schleuniger OC3950 tubing cutter was not adequately guarded to prevent employees from being in the danger zone resulting in an employee suffering a partial finger amputation
Recent events (2)
  • · I (S) $3150
  • · Z (S) $4200

1910.303 B02

Serious Gravity 1 6 instances 25 exposed
Issued
Mar 19, 2014
Abate by
Jul 31, 2014
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:     (a) Assembly area: Four outlet knock out type boxes were used as hanging pendants exposing employees to fire and electricial shock hazards.
Recent events (2)
  • · I (S) $1050
  • · Z (S) $2100

1910.305 G02 III

Serious Gravity 1 6 instances 25 exposed
Issued
Mar 19, 2014
Abate by
Jul 31, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:     (a) Assembly Area: Flexible cords running from the ceiling were stretched and pulled in such a manner as to put strain on the joints and terminals exposing employees to fire and electrical shock hazards.