AYER, MA —
OSHA Inspection: USDOJ/FBOP FEDERAL MEDICAL CENTER DEVENS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of USDOJ/FBOP FEDERAL MEDICAL CENTER DEVENS in 42 PATTON RD., AYER, MA 01432 (NAICS 922140). OSHA activity number 339637589.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- USDOJ/FBOP FEDERAL MEDICAL CENTER DEVENS
- Site address
- 42 PATTON RD.
- City
- AYER
- State
- MA
- ZIP
- 01432
- Mailing
- 42 PATTON ROAD PO BOX 880, AYER, MA 01432
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 922140
- Employees
- 543
- Ownership type
- D
Citations
9 citations on file for this inspection.
1910.22 B01
- Issued
- Apr 18, 2014
- Abate by
- May 14, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. Fence line sidewalk, FBOP Devens; The sidewalk used by employees to check the fence line was covered with snow, ice, raised filler, and steel post remnants, creating slip, trip, and fall hazards.
Recent events (1)
- — Z (S) $0
1910.22 C
- Issued
- Apr 18, 2014
- Abate by
- Apr 30, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(c): Covers and/or guardrails were not provided to protect personnel from the hazards of open pits, tanks, vats, ditches, etc. Powerhouse, FBOP Devens; Trenches in the powerhouse floor were not covered or barricaded in a manner that would prevent access to employees exposing them to trip and fall hazards.
Recent events (1)
- — Z (S) $0
1910.23 A01
- Issued
- Apr 18, 2014
- Abate by
- Oct 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(a)(1): Every stairway floor opening was not guarded by a standard railing constructed in accordance with paragraph (e) of this section on all exposed sides (except at the entrance to the stairway): Roof access hatchways, FBOP Devens; Roof access hatchways were not protected by standard railings, exposing employees to falls of over 6 feet, through the unguarded floor openings.
Recent events (1)
- — Z (S) $0
1910.132 D01
- Issued
- Apr 18, 2014
- Abate by
- Apr 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): Facility roofs, FBOP Devens; On March 12, 2014 and at times thereto, the employer did not perform a hazard assessement to determine the need for personal protective equipment for employees performing roof inspections.
Recent events (1)
- — Z (S) $0
1910.132 D01 I
- Issued
- Apr 18, 2014
- Abate by
- Apr 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: Roof, FBOP Devens; On and before March 12, 2014, corrections officers performing roof inspections were exposed to unprotected falls to the next lower level, two to three stories below.
Recent events (1)
- — Z (S) $0
1910.132 D01 III
- Issued
- Apr 18, 2014
- Abate by
- Jun 5, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(1)(iii): The employer did not select PPE that properly fit each affected employee; FBOP Devens; On and before March 12, 2014 employees were provided access to ballistic vests without being measured to ensure they fit properly.
Recent events (1)
- — Z (S) $0
1910.132 F01
- Issued
- Apr 18, 2014
- Abate by
- Jun 5, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(f)(1): The employer did not provide training to each employee who is required by this section to use personal protective equipment: Fence line, FBOP Devens; On or about March 12, 2014, employees were provided access to ice cleats but had not been provided training on their proper use and limitations.
Recent events (1)
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Apr 18, 2014
- Abate by
- Apr 30, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Power house, chemical locker, FBOP Devens; On or about March 12, 2014 the employer used a cut extension cord to wire equipment in lieu of permanent wiring.
Recent events (1)
- — Z (S) $0
1960.37 B
- Issued
- Apr 18, 2014
- Abate by
- Jun 5, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1960.37(b): The Agency's committee(s) did not have equal representation of management and nonmanagement employees: FBOP Devens; On and before March 12, 2014, the safety and health committee at the facility did not have equal representation of management and nonmanagement employees.
Recent events (1)
- — Z (O) $0
More inspections at Usdoj/Fbop Federal Medical Center Devens
View Usdoj/Fbop Federal Medical Center Devens's full OSHA safety record →
More inspections in this industry (NAICS 922140)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339637589.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.