Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: T.S. SHURE PRODUCTS

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of T.S. SHURE PRODUCTS in 1431 W. HUBBARD, CHICAGO, IL 60642 (NAICS 339930). OSHA activity number 339640286.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch T.S. Shure Products for free Get an email when a new federal OSHA severe-injury report for T.S. Shure Products is published. One employer, no account, unsubscribe in one click.
Establishment
T.S. SHURE PRODUCTS
Site address
1431 W. HUBBARD
City
CHICAGO
State
IL
ZIP
60642
Mailing
954 W. WASHINGTON ST., CHICAGO, IL 60607
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339930
Employees
2
Ownership type
Private (A)

12 citations on file for this inspection.

1910.22 B01

Serious Gravity 5 2 instances 3 exposed
Issued
Mar 28, 2014
Abate by
May 14, 2014
Penalty
Initial $1,600 · Current $1,000 Reduced
29 CFR 1910.22(b)(1): Aisles and passageways shall be kept clear and in good repairs, with no obstruction across or in aisles that could create a hazard:    On or about March 20, 2014, in the facility, employees required to perform warehouse operations were exposed to tripping hazards due to raised metal coverings/plates and floor disrepair across or in aisles and passageways.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $1600

1910.36 B01

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 28, 2014
Abate by
May 14, 2014
Penalty
Initial $1,200 · Current $800 Reduced
29 CFR 1910.36(b)(1): Two exit routes. At least two exit routes must be available in a workplace to permit prompt evacuation of employees and other building occupants during an emergency, except as allowed in paragraph (b)(3) of this section. The exit routes must be located as far away as practical from each other so that if one exit route is blocked by fire or smoke, employees can evacuate using the second exit route:    On or about March 20, 2014, in the facility, only one appropriate exit route was available to employees required to perform warehouse operations.  Therefore, employees were exposed to the hazards associated with not being able to promptly evacuate the building in the event of an emergency.
Recent events (2)
  • · I (S) $800
  • · Z (S) $1200

1910.37 B06

Serious Gravity 1 2 instances 3 exposed
Issued
Mar 28, 2014
Abate by
May 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign must be illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color. Self-luminous or electroluminescent signs that have a minimum luminance surface value of at least .06 footlamberts (0.21 cd/m2) are permitted:  On or about March 20, 2014, in the facility, the exit signs at the Sample Room were not illuminated for employees required to perform warehouse operations.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.37 B07

Serious Gravity 1 2 instances 3 exposed
Issued
Mar 28, 2014
Abate by
May 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(7): Each exit sign must have the word "Exit" in plainly legible letters not less than six inches (15.2 cm) high, with the principal strokes of the letters in the word "Exit" not less than three-fourths of an inch (1.9 cm) wide:  On or about March 20, 2014, in the facility, the word "Exit" for the exit signs at the Sample Room were not plainly legible for employees required to perform warehouse operations.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.36 G02

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 28, 2014
Abate by
May 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2): An exit access must be at least 28 inches (71.1 cm) wide at all points. Where there is only one exit access leading to an exit or exit discharge, the width of the exit and exit discharge must be at least equal to the width of the exit access:  On or about March 20, 2014, in the facility, exit access for employees required to perform warehouse operations was not at least 28 inches (71.1 cm) wide at all points due to pallets and other obstructions in aisles and passageways.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 B01

Serious Gravity 5 3 instances 3 exposed
Issued
Mar 28, 2014
Abate by
May 14, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.303(b)(1): Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees:    On or about March 20, 2014, in the facility, employees required to perform warehouse operations were exposed to the hazard of electric shock due to the following conditions:    a). Main aisle -Two-outlet electrical box with exposed live conductor(s);  b). Main aisle - Damaged electrical panel door with exposed live conductor(s);  c). Main aisle - Electrical switch with exposed live conductor(s).
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1910.141 A05

Other-than-serious 1 instance 3 exposed
Issued
Mar 28, 2014
Abate by
May 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.141(a)(5): Vermin control. Every enclosed workplace shall be so constructed, equipped, and maintained, so far as reasonably practicable, as to prevent the entrance or harborage of rodents, insects, and other vermin. A continuing and effective extermination program shall be instituted where their presence is detected:  On or about March 20, 2014, in the facility, employees required to perform warehouse operations were exposed to the hazard of rat infestation in the workplace.  A continuing and effective extermination program had not been instituted.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.141 D02 II

Other-than-serious 1 instance 3 exposed
Issued
Mar 28, 2014
Abate by
May 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(2)(ii): Each lavatory shall be provided with hot and cold running water, or tepid running water:  On or about March 20, 2014, in the facility, hot and cold running water, or tepid running water, was not provided in the lavatory for employees required to perform warehouse operations.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.141 D02 III

Other-than-serious 1 instance 3 exposed
Issued
Mar 28, 2014
Abate by
Apr 16, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(2)(iii): Hand soap or similar cleansing agents shall be provided:  On or about March 20, 2014, in the facility, hand soap or similar cleansing agents was not provided for employees required to perform warehouse operations.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.141 D02 IV

Other-than-serious 1 instance 3 exposed
Issued
Mar 28, 2014
Abate by
Apr 16, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(2)(iv): Individual hand towels or sections thereof, of cloth or paper, air blowers or clean individual sections of continuous cloth toweling, convenient to the lavatories, shall be provided:  On or about March 20, 2014, in the facility, hand towels, air blowers or continuous cloth toweling, convenient to the lavatory, was not provided for employees required to perform warehouse operations.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 E03

Other-than-serious 4 instances 3 exposed
Issued
Mar 28, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request:  On or about march 20, 2014, in the facility, the employer did not assure that portable fire extinguishers were subjected to an annual maintenance check.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 G01

Other-than-serious 1 instance 3 exposed
Issued
Mar 28, 2014
Abate by
May 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): Where the employer has provided portable fire extinguishers for employee use in the workplace, the employer shall also provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:  On or about March 20, 2014, in the facility, employees required to perform warehouse operations were provided with portable fire extinguishers in the workplace. The employer did not provide each employees with an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View T.S. Shure Products's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339640286.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.