Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MET-PRO TECHNOLOGIES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MET-PRO TECHNOLOGIES, LLC in 700 EMIEN WAY, TELFORD, PA 18969 (NAICS 333514). OSHA activity number 339641250.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Met-Pro Technologies, LLC — free Get an email when a new federal OSHA severe-injury report for Met-Pro Technologies, LLC is published. One employer, no account, unsubscribe in one click.
Site address
700 EMIEN WAY
City
TELFORD
State
PA
ZIP
18969
Mailing
700 EMIEN WAY, TELFORD, PA 18969
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333514
Employees
90
Ownership type
A

3 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 1 1 instance 95 exposed
Issued
May 2, 2014
Abate by
May 21, 2014
Penalty
Initial $1,964 · Current $1,473 Reduced
29 CFR 1910.147(c)(6)(i):   The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  (a) Production Workshop Area: On or about March 21, 2014, an employee was observed operating a band saw machine in the production workshop area where lockout/tag out was used but an inspection of the energy control procedures had not been accomplished in the last 12 months, exposing employees to injury.
Recent events (2)
  • — I (S) $1473
  • — Z (S) $1964

1910.147 C07 I A

Serious Gravity 1 1 instance 95 exposed
Issued
May 2, 2014
Abate by
May 21, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A):   Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolati:  (a) Production Workshop Area: On or about March 21, 2014, an employee was observed operating a band saw machine in the production workshop area where lockout/tag out was used but employee training was not provided, exposing employees to injury.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 5 1 instance 95 exposed
Issued
May 2, 2014
Penalty
Initial $2,225 · Current $1,669 Reduced
29 CFR 1910.242(b):   Effective chip guarding and personal protective equipment was not used when compressed air was used for cleaning purposes:  (a) Production Workshop Area: On or about March 21, 2014, an employee used an air hose that was missing a chip guard to clean (blow away) excess wood and metal shavings from equipment, exposing employee to injury from high pressure injection.
Recent events (2)
  • — I (S) $1668.75
  • — Z (S) $2225

View Met-Pro Technologies, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339641250.