CLEVELAND, OH ·
OSHA Inspection: PARAMOUNT STAMPING, WELDING & WIRE FORMING CO.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of PARAMOUNT STAMPING, WELDING & WIRE FORMING CO. in 1200 WEST 58TH STREET, CLEVELAND, OH 44102 (NAICS 332116). OSHA activity number 339641409.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PARAMOUNT STAMPING, WELDING & WIRE FORMING CO.
- Site address
- 1200 WEST 58TH STREET
- City
- CLEVELAND
- State
- OH
- ZIP
- 44102
- Mailing
- 1200 WEST 58TH STREET, CLEVELAND, OH 44102
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332116
- Employees
- 26
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.157 G02
- Issued
- May 16, 2014
- Abate by
- Jun 20, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: On or about March 20, 2014, portable fire extinguishers were available for employees to use, but initial and annual training were not provided. Note the employer may exercise one of the following options: 1. Provide portable fire extinguishers as specified in 29 CFR 1910.157(c)(1), meet the distribution requirements per 29 CFR 1910.157(d) (75 to the nearest extinguisher for Class A fires and 50 to the nearest unit for Class B fires), and provide training and education for all employees in the use of such equipment and the hazards associated with incipient stage fire fighting as specified in 29 CFR 1910.157(g). The other sections of 29 CFR also apply. 2. Provide extinguishers as specified in 29 CFR 1910.157(c)(1), designate certain employees to be the only employees authorized to use such equipment and require all other employees to immediately evacuate upon the sound of the fire alarm, establish this in writing in an emergency action plan as outlined in 29 CFR 1910.38(a) and train/educate designated employees per 1910.157(g). Utilizing this option exempts the employer from distribution requirements of 29 CFR 1910.157(d). 3. Establish a written fire safety policy which requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal. This policy shall include an emergency action plan and a fire prevention plan as specified in 29 CFR 1910.38(a) and 29 CFR 1910.39(a). Utilizing this option exempts the employer from the requirements of 29 CFR 1910.157 to include the need for providing portable fire equipment unless a specific standard requires that a portable fire extinguisher be provided (such as those requirements in 29 CFR 1910.106/107 related to the use/storage of flammable/combustible liquids). If extinguishers are provided, but not intended for employee use, 29 CFR 1910.157(e) and (f) are still applicable (inspection, maintenance, and testing of equipment).
Recent events (1)
- · Z (O) $0
1910.178 L06
- Issued
- May 16, 2014
- Abate by
- Jun 5, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): On or about March 20, 2014, the employer failed to certify the employees who operate forklifts. Note: The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training and evaluation.
Recent events (1)
- · Z (O) $0
1910.1200 E01
- Issued
- May 16, 2014
- Abate by
- Jun 20, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about March 20, 2014, the employer failed to maintain a written hazard communication program for employees exposed to chemicals including but not limited to water soluble oils, machine oil, lubricants, grease, propane, and welding gasses.
Recent events (1)
- · Z (O) $0
1910.1200 F06 II
- Issued
- May 16, 2014
- Abate by
- Jun 20, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: On or about March 20, 2014, the employer failed to label each secondary bottle of chemicals, including the soda bottles used for oils in the Tool and Die Department and the 55 gallon drum of water soluble oil located in the Press Room.
Recent events (1)
- · Z (O) $0
1910.1200 H03 IV
- Issued
- May 16, 2014
- Abate by
- Jun 20, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: On or about March 20, 2014, the employer failed to provide updated training on Safety Data Sheets and labeling for employees exposed to chemicals including but not limited to water soluble oils, machine oil, lubricants, grease, propane, and welding gasses.
Recent events (1)
- · Z (O) $0
More inspections at Paramount Stamping, Welding & Wire Forming CO.
View Paramount Stamping, Welding & Wire Forming CO.'s full OSHA safety record →
More inspections in this industry (NAICS 332116)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339641409.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.