BALDWIN, NY —
OSHA Inspection: DELCID HOME IMPROVEMENT CONTRACTOR CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DELCID HOME IMPROVEMENT CONTRACTOR CORP. in 1021 THOMAS AVE., BALDWIN, NY 11510 (NAICS 236118). OSHA activity number 339642035.
Where did this inspection happen?
- Establishment
- DELCID HOME IMPROVEMENT CONTRACTOR CORP.
- Site address
- 1021 THOMAS AVE.
- City
- BALDWIN
- State
- NY
- ZIP
- 11510
- Mailing
- 1030 WASHINGTON AVE., WESTBURY, NY 11590
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.95 A
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $600.00 Reduced
General-duty citation text
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. a) worksite - An employee installing shingles with a pneumatic nail gun was not using eye protection; on or about 03/21/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.100 A
- Issued
- Penalty
- Initial $1200.00 · Current $600.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite - Employees working directly under ongoing roofwork were not wearing head protection; on or about 03/21/2013. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.501 B13
- Issued
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) worksite - Employees working on an approximate 10-12 pitch roof, approximately 22 feet above the ground were not protected from falling; on or about 03/21/14. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.1053 B01
- Issued
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) worksite - Employees were using an unsecured ladder to gain access to the roof. The ladder side rails were approximately 4 inches above the upper landing; on or about 03/21/14. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
More inspections in this industry (NAICS 236118)
BROOKLYN, NY—2026-07-15
MEGA GENERAL CONSTRUCTION NYC INC.
BROOKLYN, NY—2026-07-15
MEGA GENERAL CONSTRUCTION NYC INC.
SYRACUSE, NY—2026-07-14
EMPIRE BUILDERS OF CNY, INC.
RENTON, WA—2026-07-14
WA317992055 - JCC INVESTMENT GROUP LLC
RIVERTON, NJ—2026-07-14
JBF CONSTRUCTION LLC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source