Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: WELCH PACKAGING

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of WELCH PACKAGING in 6969 ALUM CREEK DR., COLUMBUS, OH 43217 (NAICS 322211). OSHA activity number 339644932.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Welch Packaging for free Get an email when a new federal OSHA severe-injury report for Welch Packaging is published. One employer, no account, unsubscribe in one click.
Establishment
WELCH PACKAGING
Site address
6969 ALUM CREEK DR.
City
COLUMBUS
State
OH
ZIP
43217
Mailing
6969 ALUM CREEK DR., COLUMBUS, OH 43217
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322211
Employees
40
Ownership type
Private (A)

2 citations on file for this inspection.

1910.178 L04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 25, 2014
Penalty
Initial $3,400 · Current $2,380 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years.  a. At the workplace, the employer did not ensure the each powered industrial truck operator had their performance revaluated at least once every three years.
Recent events (2)
  • · I (S) $2380
  • · Z (S) $3400

1910.305 G01 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 25, 2014
Penalty
Initial $3,400 · Current $2,380 Reduced
Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used:  29 CFR 1910.305(g)(1)(iv)(A): As a substitute for the fixed wiring of a structure   a. In the Pit Area at the workplace, the employer used a flexible cord to supply power to a submersible pump used for evacuating water.
Recent events (2)
  • · I (S) $2380
  • · Z (S) $3400

View Welch Packaging's full OSHA safety record →