CHEEKTOWAGA, NY ·
OSHA Inspection: TOTAL FACILITY CARE, INC.
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of TOTAL FACILITY CARE, INC. in 4635 UNION ROAD, CHEEKTOWAGA, NY 14225 (NAICS 561720). OSHA activity number 339646861.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TOTAL FACILITY CARE, INC.
- Site address
- 4635 UNION ROAD
- City
- CHEEKTOWAGA
- State
- NY
- ZIP
- 14225
- Mailing
- 85 BENBRO DRIVE, CHEEKTOWAGA, NY 14225
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561720
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.134 C01
- Issued
- Jun 16, 2014
- Abate by
- Jul 19, 2014
- Penalty
- Initial $1,890 · Current $1,418 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (Construction Reference 1926.103) a) Aspire Building, 4635 Union Rd, Cheektowaga, NY - On or about 3/25/14, the employer had not developed and implemented a written respiratory protection program for employees who are required, by the employer, to wear filtering face-piece respirators while removing floor tiles and sweeping up debris. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $1417.5
- · Z (S) $1890
1910.134 E01
- Issued
- Jun 16, 2014
- Abate by
- Jun 26, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees' ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103) a) Aspire Building, 4635 Union Rd, Cheektowaga, NY - On or about 3/25/14, the employer did not provide a medical evaluation to employees who are required, by the employer, to wear filtering face-piece respirators while removing floor tile and sweeping debris. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 F02
- Issued
- Jun 16, 2014
- Abate by
- Jul 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (Construction Reference 1926.103) a) Aspire Building, 4635 Union Rd, Cheektowaga, NY - On or about 3/25/14, employees who were required, by the employer, to wear filtering face-piece respirators while removing tile and sweeping debris. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 K01
- Issued
- Jun 16, 2014
- Abate by
- Jul 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(1): The employer did not provide effective training to employees who are required to wear respirators and ensure that they could demonstrate knowledge of the requirements contained in 1910.134(k)(1)(i) through 1910.134(k)(1)(vii): a) Aspire Building, 4635 Union Rd, Cheektowaga, NY - On or about 3/25/14, the employer did not provide training to employees who are required, by the employer, to wear filtering face-piece respirators while removing floor tile and sweeping debris. The employees could not demonstrate knowledge of at least the following: 1) Why the respirator is necessary and how improper fit, usage, or maintenance can compromise the protective fit of the respirator; 2) What the limitations and capabilities of the respirator are; 3) How to inspect, put on and remove, and check the seals of the respirator; 4) How to recognize medical signs and symptoms that may limit or prevent the effective use of the respirator; AND 5) The general requirements of this section. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Total Facility Care, INC.
View Total Facility Care, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 561720)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339646861.