OLD WESTBURY, NY —
OSHA Inspection: C AND C SIDING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of C AND C SIDING in 5 ELMHURST DR., OLD WESTBURY, NY 11568 (NAICS 238170). OSHA activity number 339647158.
Where did this inspection happen?
- Establishment
- C AND C SIDING
- Site address
- 5 ELMHURST DR.
- City
- OLD WESTBURY
- State
- NY
- ZIP
- 11568
- Mailing
- 12 PUMPKIN ST, EAST NORTHPORT, NY 11731
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 C02 II
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: a) Worksite: Employees were working from a ladder jack scaffold that was not properly secured; on or about 3/25/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1926.451 G01 I
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1960.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) Worksite: An employee installing siding on a new residential construction approximately 12 feet above the ground from a ladder jack scaffold was not protected from falling; on or about 3/25/14. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1926.1053 B16
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $840.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: a) Worksite: Employees were using a ladder with a damaged ladder rung that was held together with duct tape for a ladder jack scaffold, on or about 3/25/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
More inspections in this industry (NAICS 238170)
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16