Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NICHOLS CUSTOM STAINLESS MANUFACTURING, LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of NICHOLS CUSTOM STAINLESS MANUFACTURING, LLC in 8500 NE UNDERGROUND DRIVE, KANSAS CITY, MO 64161 (NAICS 337124). OSHA activity number 339647208.

Watch Nichols Custom Stainless Manufacturing, LLC — free Get an email when a new federal OSHA severe-injury report for Nichols Custom Stainless Manufacturing, LLC is published. One employer, no account, unsubscribe in one click.
Site address
8500 NE UNDERGROUND DRIVE
City
KANSAS CITY
State
MO
ZIP
64161
Mailing
8500 NE UNDERGROUND DRIVE, KANSAS CITY, MO 64161
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337124
Employees
9
Ownership type
A

5 citations on file for this inspection.

1910.305 B02 I

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $0.00 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:     (a) Employee(s) were exposed to electrical hazards in the conference room created by an duplex receptacle that did not have a face plate.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1600

1910.305 G01 IV

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $0.00 Reduced
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv):     (a) Employee(s) were exposed to electrical hazards caused by a yellow flexible extension cord plugged into an outlet in the conference room. The yellow extension cord was incorrectly used to power an air conditioner and other equipment in the front office in that it passed through a doorway and was used instead of permanent wiring.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1600

1910.1026 L01

Serious Gravity 1 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced

Hazardous substances 06890691

29 CFR 1910.1026(l)(1): The employer did not ensure that all employees who were assigned to workplaces where there was exposure to chromium (VI) were provided with information and training as required by the Hazard Communication Standard 29 CFR 1910.1200:  (a) The employer did not ensure that all employees who were exposed to hexavalent chromium, created during stainless steel welding were provided with information and training as required by the Hazard Communication Standard 29 CFR 1910.1200. Prolonged inhalation of fume may cause lung, central nervous system, liver, kidney, and nasal cavity damage.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.1026 L02

Serious Gravity 1 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 06890694

29 CFR 1910.1026(l)(2): 29CFR 1910.1026(l)(2): The employer did not ensure that employees could demonstrate knowledge of the contents of this section and the purpose of medical surveillance; and in addition the employer did not make a copy of this section available without cost to all affected employees:  (a) Employees were exposed to hexavalent chromium, created during stainless steel welding. Prolonged inhalation of fume may cause lung, central nervous system, liver, kidney, and nasal cavity damage. Employer did not ensure employees could demonstrate knowledge of the contents of this section and did not make a copy of this section available to all affected employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 06890691

29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:   (a) Employees were exposed to hazardous chemicals such as nickel and hexavalent chromium, created when welding stainless steel. Prolonged inhalation of metal fume may cause lung, central nervous system, liver, kidney, and nasal cavity damage. A written hazard communication program was not developed, implemented or maintained at the workplace at the time of this inspection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339647208.