Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: OSCAR EDGAR HERNANDEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of OSCAR EDGAR HERNANDEZ in 3112 NEWTON ST., NE, WASHINGTON, DC 20018 (NAICS 238170). OSHA activity number 339648347.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Oscar Edgar Hernandez for free Get an email when a new federal OSHA severe-injury report for Oscar Edgar Hernandez is published. One employer, no account, unsubscribe in one click.
Site address
3112 NEWTON ST., NE
City
WASHINGTON
State
DC
ZIP
20018
Mailing
7312 MENDOTA AVE., FALLS CHURCH, VA 22042
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
3
Ownership type
Private (A)

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 18, 2014
Abate by
Apr 24, 2014
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:  a) An employee was using a pneumatic nail gun without eye protection exposing him to a struck-by hazard, on or about 03/24/14.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • · Z (S) $1200

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 18, 2014
Abate by
Apr 24, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) An employee without fall protection was exposed to a fall hazard of approximately 14 feet 8 inches from the porch roof, on or about 03/24/14.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • · Z (S) $2000

1926.503 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 18, 2014
Abate by
Jun 5, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a) An employee without fall protection was exposed to a fall hazard of approximately 14 feet 8 inches from the porch roof and no training was provided, on or about 03/24/14.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • · Z (S) $0

1926.1052 C01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 18, 2014
Abate by
Apr 24, 2014
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:   a) Two employees were using the porch stairs which were 9 risers in height and not equipped with stairrails exposing them to a fall hazard, on or about 03/24/14.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • · Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339648347.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.