Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ASCENCION MARTINEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ASCENCION MARTINEZ in 14346 FOSTERS RUN LN., HUMBLE, TX 77396 (NAICS 238310). OSHA activity number 339649089.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ascencion Martinez — free Get an email when a new federal OSHA severe-injury report for Ascencion Martinez is published. One employer, no account, unsubscribe in one click.
Establishment
ASCENCION MARTINEZ
Site address
14346 FOSTERS RUN LN.
City
HUMBLE
State
TX
ZIP
77396
Mailing
6812 DIONNE ST., HOUSTON, TX 77076
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.403 B01 I

Other-than-serious 1 instance 2 exposed
Issued
Apr 24, 2014
Abate by
May 13, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose.   The employer does not determine the safety of equipment as identified by its listing, labeling or certification. This violation was observed on or about March 25, 2014, in the NE corner of a single family dwelling where employees were using a relocatable power tap to power a DeWalt Spade Handle Drill. Relocatable power taps are not approved for use at construction sites.   Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that the safety of equipment is determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.405 G02 IV

Other-than-serious 2 instances 2 exposed
Issued
Apr 24, 2014
Abate by
May 13, 2014
Penalty
Initial $400 · Current $240 Reduced
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:   The employer does not ensure that flexible cords are provided strain relief.     a. This violation was observed on or about March 25, 2014, in the NE corner of a single family dwelling where employees were using a relocatable power tap to power a DeWalt Spade Handle Drill and strain relief was not provided on the cord. No energized wiring was visible and the power tap was plugged into a functioning GFCI outlet.   b. This violation was observed on or about March 25, 2014, on the rear of a single family dwelling where employees were using a 50 foot electrical cord without strain relief being provided at the female end. No energized wiring was visible and the electrical cord was plugged into a functioning GFCI outlet.   Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that flexible cords are connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws.
Recent events (2)
  • — I (O) $240
  • — Z (O) $400

1926.416 E01

Other-than-serious 2 instances 2 exposed
Issued
Apr 24, 2014
Abate by
May 13, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:   The employer uses worn or frayed electric cords.      a. This violation was observed on or about March 25, 2014, on the rear of a single family dwelling where employees were using a red and black 50 foot electric cord that had numerous cuts on the outer covering. No energized wiring was visible and the cord was plugged into a functioning GFCI outlet.    b. This violation was observed on or about March 25, 2014, on the rear corner of a single family dwelling where employees were using a yellow 50 foot electrical cord that had numerous cuts on the outer covering. No energized wiring was visible and the electrical cord was plugged into a functioning GFCI outlet.   Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that worn or frayed electric cords are not used.