Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: MANNPOWER HANDYMAN

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MANNPOWER HANDYMAN in 700 HAGGERTY LANE, BOZEMAN, MT 59718 (NAICS 236116). OSHA activity number 339649824.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mannpower Handyman for free Get an email when a new federal OSHA severe-injury report for Mannpower Handyman is published. One employer, no account, unsubscribe in one click.
Establishment
MANNPOWER HANDYMAN
Site address
700 HAGGERTY LANE
City
BOZEMAN
State
MT
ZIP
59718
Mailing
95 REDWOOD DR., BOZEMAN, MT 59718
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
2
Ownership type
Private (A)

6 citations on file for this inspection.

1926.404 F06

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Aug 7, 2014
Abate by
Sep 3, 2014
Penalty
Initial $2,400 · Current $0 Reduced
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  (a) Construction site: On or about February 20, 2014 and at times prior, employees were exposed to shock hazards from a flexible extension cord that did not provide a complete ground circuit, and was being used to energize the Bosch PowerBox radio.                    (b) Construction site: On or about February 20, 2014 and at times prior, employees were exposed to shock hazards from a flexible extension cord that did not provide a complete ground circuit, and was being used to energize the Worm Drive Skill Saw.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2400

1926.405 G02 IV

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Aug 7, 2014
Abate by
Sep 3, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  (a) Construction site: On or about February 20, 2014, and at times prior, employees were exposed to shock hazards when using damaged flexible extension cords to energize the Bosch PowerBox radio.  (b) Construction site: On or about February 20, 2014, and at times prior, employees were exposed to shock hazards when using damaged flexible extension cords to energize the Worm Drive Skill Saw.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 B03

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Aug 7, 2014
Abate by
Sep 3, 2014
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.451(b)(3): Where guardrails were not installed along the front edge of the platform or all employees were not protected from falling with the use of personal fall arrest systems, the front edge of the scaffold platform was more than 14 inches from the front working surface:  (a) Construction site: On or about February 20, 2014, and at times prior, employees were exposed to a fall hazard of approximately 14 feet to the ground below while installing siding from a pump jack scaffold.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

1926.451 E01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Aug 7, 2014
Abate by
Sep 3, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used:   (a) Construction site: On or about February 20, 2014, and at times prior, employees were exposed to a fall hazard of approximately 14 feet to the ground below in the event of scaffolding failure while installing siding from a pump jack scaffolding without adequate means to egress.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 G01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Aug 7, 2014
Abate by
Sep 3, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level:  (a) Construction site: On or about February 20, 2014, and at times prior, employees were exposed to a fall hazard of approximately 14 feet to the ground below while installing siding from an unguarded, pump jack scaffolding.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.1053 B05 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Aug 7, 2014
Abate by
Sep 3, 2014
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder:  (a) Construction site: On February 20, 2014 and at time prior, employees were exposed to a fall hazard of approximately 14 feet to the ground below while using an extendable metal ladder to access and egress an elevated platform.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2000