GARLAND, TX —
OSHA Inspection: INTERCERAMIC INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of INTERCERAMIC INC. in 2333 S. JUPITER ROAD, GARLAND, TX 75041 (NAICS 327122). OSHA activity number 339649972.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INTERCERAMIC INC.
- Site address
- 2333 S. JUPITER ROAD
- City
- GARLAND
- State
- TX
- ZIP
- 75041
- Mailing
- 2333 S. JUPITER ROAD, GARLAND, TX 75041
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327122
- Employees
- 150
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.134 E01
- Issued
- Jul 1, 2014
- Abate by
- Jul 28, 2014
- Penalty
- Initial $4,000 · Current $2,400 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: This violation was discovered on or about April 2, 2014, in the body prep department, where employees wearing elastomeric half mask respirators had not been medically evaluated to determine their fitness to wear the respirators.
Recent events (2)
- — I (S) $2400
- — Z (S) $4000
1910.147 C01
- Issued
- Jul 1, 2014
- Abate by
- Jul 28, 2014
- Penalty
- Initial $5,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: This violation was discovered on or about April 2, 2014, when the employer had not established a program consisting of energy control procedures, employee training, and periodic inspections to ensure the control of hazardous energy during servicing or maintenance of equipment including, but not limited to, sacmi hydraulic presses.
Recent events (2)
- — I (S) $3000
- — Z (S) $5000
1910.151 C
- Issued
- Jul 1, 2014
- Abate by
- Oct 1, 2014
- Penalty
- Initial $5,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: This violation was discovered on or about April 2, 2014, in the body prep department, where employees who worked with injurious corrosive materials, including defloc and refrix, were not provided with a suitable facility for quick drenching or flushing of the eyes and body.
Recent events (2)
- — I (S) $3000
- — Z (S) $5000
1910.305 B01 II
- Issued
- Jul 1, 2014
- Penalty
- Initial $4,000 · Current $2,400 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: This violation was discovered on or about March 25, 2014, at line #3 stacker machine, where two electrical outlet boxes had missing knockouts.
Recent events (2)
- — I (S) $2400
- — Z (S) $4000
1910.305 G02 III
- Issued
- Jul 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: This violation was discovered on or about March 25, 2014, when the outer insulation to a flexible cord supplying power to a 220-volt motor had separated from the fitting, exposing inner conductors to strain: a) At line #2 grouper b) At line #1 loader
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Jul 1, 2014
- Abate by
- Jul 28, 2014
- Penalty
- Initial $5,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: This violation was discovered on or about March 25, 2014, when the employer had not provided employees with training on the hazards of the chemicals in their work area: a) In the body prep department, employees had not been trained on the hazards associated with defloc and refrix. b) In the press department, employees had not been trained on the hazards associated with materials containing silica.
Recent events (2)
- — I (S) $3000
- — Z (S) $5000
More inspections at Interceramic INC.
View Interceramic INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327122)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339649972.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.