MILWAUKEE, WI ·
OSHA Inspection: TIMBER CREEK RESOURCE, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TIMBER CREEK RESOURCE, LLC in 5059 N. 119TH STREET, MILWAUKEE, WI 53225 (NAICS 321920). OSHA activity number 339652380.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TIMBER CREEK RESOURCE, LLC
- Site address
- 5059 N. 119TH STREET
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53225
- Mailing
- 5059 N. 119TH STREET, MILWAUKEE, WI 53225
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 148
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.213 I01
- Issued
- Jul 14, 2014
- Penalty
- Initial $3,825 · Current $1,913 Reduced
General-duty citation text
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded: (a) On or about March 28, 2014 the Centauro vertical band saw was identified cutting wood product with approximately 2.5 inches of unused blade exposed.
Recent events (2)
- · I (S) $1912.5
- · Z (S) $3825
1910.303 B02
- Issued
- Jul 14, 2014
- Penalty
- Initial $1,951 · Current $976 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) In the Parts Mill / Cell 3, two DeWalt Miter saws were plugged into a relocatable power tap which was daisy chained to an extension cord to provide power from a receptacle.
Recent events (2)
- · I (S) $975.5
- · Z (S) $1951
1910.305 G02 III
- Issued
- Jul 14, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: (a) In Cell 3 / Assembly, the Bosch CS20 circular saw did not have strain relief provided where the power cord connected to the saw.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.38 C02
- Issued
- Jul 14, 2014
- Abate by
- Jul 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.38(c)(2): The emergency action plan did not include procedures for emergency evacuation, including type of evacuation and exit route assignments: (a) The employer did not ensure their emergency action plan was updated to reflect current policy for evacuation. The written program indicated trained personnel should attempt to fight fires with fire extinguishers whereas the employer's policy was to evacuate the workplace.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Timber Creek Resource, LLC
View Timber Creek Resource, LLC's full OSHA safety record →
More inspections in this industry (NAICS 321920)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339652380.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.