OSHA Inspection: TIMBER CREEK RESOURCE, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TIMBER CREEK RESOURCE, LLC in 5059 N. 119TH STREET, MILWAUKEE, WI 53225 (NAICS 321920). OSHA activity number 339652380.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Timber Creek Resource, LLC for free Get an email when a new federal OSHA severe-injury report for Timber Creek Resource, LLC is published. One employer, no account, unsubscribe in one click.
Site address
5059 N. 119TH STREET
City
MILWAUKEE
State
WI
ZIP
53225
Mailing
5059 N. 119TH STREET, MILWAUKEE, WI 53225
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
148
Ownership type
Private (A)

4 citations on file for this inspection.

1910.213 I01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 14, 2014
Penalty
Initial $3,825 · Current $1,913 Reduced
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded:    (a) On or about March 28, 2014 the Centauro vertical band saw was identified cutting wood product with approximately 2.5 inches of unused blade exposed.
Recent events (2)
  • · I (S) $1912.5
  • · Z (S) $3825

1910.303 B02

Serious Gravity 1 2 instances 2 exposed
Issued
Jul 14, 2014
Penalty
Initial $1,951 · Current $976 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) In the Parts Mill / Cell 3, two DeWalt Miter saws were plugged into a relocatable power tap which was daisy chained to an extension cord to provide power from a receptacle.
Recent events (2)
  • · I (S) $975.5
  • · Z (S) $1951

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  (a)  In Cell 3 / Assembly, the Bosch CS20 circular saw did not have strain relief provided where the power cord connected to the saw.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.38 C02

Other-than-serious 1 instance 110 exposed
Issued
Jul 14, 2014
Abate by
Jul 31, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.38(c)(2): The emergency action plan did not include procedures for emergency evacuation, including type of evacuation and exit route assignments:  (a)  The employer did not ensure their emergency action plan was updated to reflect current policy for evacuation. The written program indicated trained personnel should attempt to fight fires with fire extinguishers whereas the employer's policy was to evacuate the workplace.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Timber Creek Resource, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339652380.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.