WASHINGTON, DC —
OSHA Inspection: PROSPECT WATERPROOFING COMPANY
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of PROSPECT WATERPROOFING COMPANY in 2201 M ST., NW, WASHINGTON, DC 20037 (NAICS 238990). OSHA activity number 339658528.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROSPECT WATERPROOFING COMPANY
- Site address
- 2201 M ST., NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20037
- Mailing
- 118 ACACIA LANE, STERLING, VA 20166
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 150
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B10
- Issued
- Apr 30, 2014
- Abate by
- May 6, 2014
- Penalty
- Initial $4,500 · Current $3,375 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. a) Employee applying tar to the roof of the canopy where it meets the building without fall protection, exposing him to an 18 foot fall hazard, on or about 03/31/14. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $3375
- — Z (S) $4500
1926.1053 B01
- Issued
- Apr 30, 2014
- Abate by
- May 6, 2014
- Penalty
- Initial $3,600 · Current $2,700 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) An employee accessed a canopy roof using an extension ladder which extended approximately 15 inches above the landing exposing the employee to a fall hazard, on or about 03/31/14. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $2700
- — Z (S) $3600
More inspections at Prospect Waterproofing Company