OSHA Inspection: RECO OF ILLINOIS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RECO OF ILLINOIS, INC. in 1669 DEARBORN, AURORA, IL 60505 (NAICS 332710). OSHA activity number 339659054.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Reco of Illinois, INC. for free Get an email when a new federal OSHA severe-injury report for Reco of Illinois, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1669 DEARBORN
City
AURORA
State
IL
ZIP
60505
Mailing
1669 DEARBORN, AURORA, IL 60505
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
5
Ownership type
Private (A)

17 citations on file for this inspection.

1910.23 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 5, 2014
Abate by
Oct 10, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers shall be equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section, the width of the stair to be measured clear of all obstructions except handrails:    In Bay 1, the stair way that leads to the mezzanine level did not have a mid rail and the post for the top rail was broken off at the floor. This compromised the integrity and the strength of the hand rail. Employees were exposed to a fall hazard.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.36 D01

Serious Gravity 10 8 instances 2 exposed
Issued
Sep 5, 2014
Abate by
Sep 15, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge.     (a) In Bay #8, emergency exit doors #1 and #2 were blocked by machinery and locked, preventing employees from exiting the building in case of an emergency.      (b) In Bay #7, emergency exit door #3 was blocked by propane tank and locked, preventing employees from exiting the building in case of an emergency.     (c) In Bay #5 and #6 emergency exit door was blocked by machinery and locked, preventing employees from exiting the building in case of an emergency.     (d) In Bay #2 emergency exit door #8 was welded shut and emergency exit #9 was locked, preventing employees from exiting the building in case of an emergency.     (e) In Bay #1, emergency exit door #10, was locked, preventing employees from exiting the building incase of an emergency.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.37 A03

Serious Gravity 10 6 instances 2 exposed
Issued
Sep 5, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit routes were not free and/or unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route.   Six emergency exit doors in the facility were blocked. Employees working throughout the facility were exposed to fire hazards in the event of an emergency.  Abatement documentation is not required.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.37 B02

Serious Gravity 10 10 instances 2 exposed
Issued
Sep 5, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.37(b)(2): Each exit must be clearly visible and marked by a sign reading "Exit."    Facility- All ten emergency exits in the facility were not marked.    Abatement documentation is not required.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.147 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 5, 2014
Abate by
Oct 10, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    The employer did not establish a program for the control of hazardous energy (lockout/tagout) for when the employees performed servicing (set-up) on production machinery, such as, but no limited to power press brakes and mechanical shears.  Employees were exposed to amputation hazards.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d)
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.147 C05 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 5, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware shall be provided by the employer for isolating, securing or blocking of machines or equipment from energy sources.    The employer did not provide lockout locks, tags, or hardware for the employees to utilize in the event that a machine needed to be placed in a zero energy state. This exposed employees to amputation hazards.    Abatement documentation is not required for this item.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.157 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 5, 2014
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.157(e)(1): The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace.    The employer did not conduct inspections or maintain the fire extinguishers that were provided.     Certification is not required for this item.
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1910.178 L01 I

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 5, 2014
Abate by
Oct 10, 2014
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.178(l)(1)(i): The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    The employer did not ensure that the forklift operators were trained and evaluated in the safe operation of powered industrial trucks. Employees were exposed to struck-by and crushed-by hazards.    Abatement documentation is required for this item in accordance with 28 CFR 1903.19(d)
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1910.213 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 5, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.213(g)(1): Each swing cutoff saw shall be provided with a hood that will completely enclose the upper half of the saw, the arbor end, and the point of operation at all positions of the saw. The hood shall be constructed in such a manner and of such material that it will protect the operator from flying splinters and broken saw teeth. Its hood shall be so designed that it will automatically cover the lower portion of the blade, so that when the saw is returned to the back of the table the hood will rise on top of the fence, and when the saw is moved forward the hood will drop on top of and remain in contact with the table or material being cut.    The employer failed to provide methods of machine guarding that would protect employees while operating the Rigid chop saw. The saw did not have the blade guard installed. This exposed employees to lacerations and/or amputations upon accidental contact with the rotating blade.    No abatement documentation is required for this item.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.253 B02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 5, 2014
Abate by
Sep 15, 2014
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.253(b)(2)(ii):   Cylinders were not stored in areas to ensure that the cylinders would not be knocked over:    In Bay 5 a oxygen cylinder was not properly secured to prevent the cylinder from being knocked over or damaged.    Abatement documentation is required for this item in accordance with 19 CFR 1903.19(d)
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1910.253 B02 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 5, 2014
Abate by
Sep 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use.  In Bay 5 an oxygen cylinder was stored without the valve protection cap installed.  The valve was therefore susceptible to damage and foreign object entry.  Abatement documentation is required for this item in accordance with 29 CFR 1910.19(d)
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 5, 2014
Abate by
Sep 15, 2014
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.    The employer failed to install and use equipment in accordance with the instructions listed and permitted uses. A knockout type box was installed as a pendant extension cord and used in the production area near the paint booth in bay 1. Employees were exposed to a shock hazard.    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1910.305 G01 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 5, 2014
Abate by
Sep 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used.  Bay 1: Flexible cords were used as permanent wiring when used with a light near the paint booth. This exposed employees to electrical shock hazards.  Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d)
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 B01 II

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 5, 2014
Abate by
Sep 25, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed.    The employer failed to adequately close unused openings in electrical boxes located in the following areas:    a. Bay 5/6: Located near the work bench.    b. Bay 7: Near the walk through area on the wall.     This exposed employees to electrical shock hazards.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.305 B02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 5, 2014
Abate by
Sep 25, 2014
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.    The employer failed to provide faceplate covers for electrical boxes. This exposed employees to electrical shock hazards.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d)
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1910.305 D02

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 5, 2014
Abate by
Oct 10, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.305(d)(2): Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons.    The employer failed to adequately install panelboards for the electrical boxes through out the facility. This exposed employees to shock and electrocution hazards.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.141 D01

Other-than-serious 2 instances 2 exposed
Issued
Sep 5, 2014
Abate by
Oct 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(1): Washing facilities were not maintained in a sanitary condition.  The employer did not maintain restroom facilities in a sanitary condition.  Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d)
Recent events (2)
  • · I (O) $0
  • · Z (O) $0