CAMP PENDLETON, CA ·
OSHA Inspection: MAINTENANCE CENTER BARSTOW
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of MAINTENANCE CENTER BARSTOW in BLDG 21668 12TH STREET, CAMP PENDLETON, CA 92055 (NAICS 811111). OSHA activity number 339659641.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAINTENANCE CENTER BARSTOW
- Site address
- BLDG 21668 12TH STREET
- City
- CAMP PENDLETON
- State
- CA
- ZIP
- 92055
- Mailing
- MARINE CORPS LOGISTICS COMMAND WAREHOUSE 405 WEST END, BARSTOW, CA 93311
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 15
- Ownership type
- Federal government (D)
Citations
4 citations on file for this inspection.
1910.134 E01
- Issued
- Jul 24, 2014
- Abate by
- Aug 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: At the Corrosion control facility - On or about 4/7/2014, and at times prior thereto, the employer did not provide a medical evaluation prior to respirator use.
Recent events (1)
- · Z (S) $0
1910.134 F01
- Issued
- Jul 24, 2014
- Abate by
- Aug 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): At the Corrosion control facility - On or about 4/7/2014, and at times prior thereto, the employer did not ensure that employees passed a fit test prior to respirator use.
Recent events (1)
- · Z (S) $0
1910.134 F02
- Issued
- Jul 24, 2014
- Abate by
- Aug 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested whenever a different respirator facepiece (size, style, model or make) was used: At the Corrosion control facility - On or about 4/7/2014, and at times prior thereto, the employer did not ensure that employees passed a fit test prior when a different respirator was used.
Recent events (1)
- · Z (S) $0
1910.134 G01 I A
- Issued
- Jul 24, 2014
- Abate by
- Aug 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: At the Corrosion control facility - On or about 4/7/2014, and at times prior thereto, the employer did not ensure that employees who had facial hair were prevented from wearing respirators.
Recent events (1)
- · Z (S) $0
More inspections in this industry (NAICS 811111)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339659641.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.