Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PARADIGM CONSTRUCTION GROUP OF SOUTH FLORIDA, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PARADIGM CONSTRUCTION GROUP OF SOUTH FLORIDA, INC. in 1800 S. OCEAN DRIVE, HALLANDALE BEACH, FL 33009 (NAICS 238140). OSHA activity number 339659880.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Paradigm Construction Group of South Florida, INC. — free Get an email when a new federal OSHA severe-injury report for Paradigm Construction Group of South Florida, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1800 S. OCEAN DRIVE
City
HALLANDALE BEACH
State
FL
ZIP
33009
Mailing
10396 W STATE ROAD 84 # 109, DAVIE, FL 33324
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
50
Ownership type
A

7 citations on file for this inspection.

1926.405 A02 II I

Serious Gravity 5 1 instance 16 exposed
Issued
Aug 5, 2014
Penalty
Initial $3,500 · Current $1,925 Reduced
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage:    a. On or about April 2, 2014 at the above addressed job site, employees who had been performing concrete restoration work, were exposed to shock and electrocution hazards while using swing stage scaffolds which were powered by electrical cords that had passed over thresholds of doors and had not been protected from damage.
Recent events (2)
  • — I (S) $1925
  • — Z (S) $3500

1926.451 B01

Serious Gravity 10 7 instances 16 exposed
Issued
Aug 5, 2014
Abate by
Aug 15, 2014
Penalty
Initial $6,300 · Current $3,465 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):    a)  On or about April 2, 2014, at the above addressed job site, employees who had been erecting and maintaining suspended swing stage scaffolds, were exposed to a fall hazard while working on fabricated frame scaffolds that were not fully planked.      7 instances: 7 ea. fabricated frame scaffolds were erected on the roof area to support the installation and maintenance of 7 ea. suspended swing stage scaffolds, and each lacked planking on the upper level where employees had been working.    PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED.
Recent events (2)
  • — I (S) $3465
  • — Z (S) $6300

1926.451 D03 X

Serious Gravity 10 14 instances 16 exposed
Issued
Aug 5, 2014
Abate by
Aug 15, 2014
Penalty
Initial $6,300 · Current $3,465 Reduced
29 CFR 1926.451(d)(3)(x): Single tiebacks were installed at an angle:    a. On or about April 2, 2014, at the above addressed job site, employees who had been performing concrete restoration work from suspended swing stage scaffolds were exposed to fall hazards as the scaffolds had been suspended from parapet clamps that had single tie backs that had been installed at an angle to the face of the building.     14 Instances: 7 suspended scaffolds each suspended by 2 parapet clamps.     PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED.
Recent events (2)
  • — I (S) $3465
  • — Z (S) $6300

1926.451 D12

Serious Gravity 5 7 instances 16 exposed
Issued
Aug 5, 2014
Abate by
Aug 15, 2014
Penalty
Initial $4,500 · Current $2,475 Reduced
29 CFR 1926.451(d)(12)(iv) Wire rope clips used on suspension scaffold ropes were not installed according to the manufacturer's recommendations; were not retightened to the manufacturer's recommendations loading and at the start of each work shift:    a.  On or about April 2, 2014, at the above addressed job site, employees who had been performing concrete restoration work were exposed to a fall hazard while using swing stage scaffolds which had been suspended and secured by wire ropes which had clips that had not been retightened to the manufacturer's recommendations at the start of each work shift.    28 instances: 7 suspended scaffolds each suspended by 2 wire ropes, with 2 tiebacks that each had a wire rope clips.    PLEASE NOTE THAT DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED.
Recent events (2)
  • — I (S) $2475
  • — Z (S) $4500

1926.451 F03

Serious Gravity 10 14 instances 16 exposed
Issued
Aug 5, 2014
Abate by
Aug 15, 2014
Penalty
Initial $6,300 · Current $3,465 Reduced
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:    a. On or about April 2, 2014, at the above addressed job site, employees who had been performing concrete restoration work from deficient suspended swing stage scaffolds and fabricated frame scaffolds, were exposed to fall hazards as the scaffolds had not been inspected by a competent person before each work shift and had the following deficiencies:    14 Instances: There were 7 ea. swing stage scaffolds that each had a fabricated frame scaffold.    1.The 7 fabricated frame scaffolds were lacking planking, and guardrails.  2. Swing stage scaffolds which had been suspended and secured by wire ropes which had clips that had not been retightened to the manufacturer's recommendations at the start of each work shift.  3. Vertical lifelines that had been used on swing stage scaffolds had been tied to anchorages with knots.   4. Single tiebacks had been installed at angles to the face of the building.      PLEASE NOTE THAT DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED.
Recent events (2)
  • — I (S) $3465
  • — Z (S) $6300

1926.451 G01 VII

Serious Gravity 10 7 instances 16 exposed
Issued
Aug 5, 2014
Abate by
Aug 15, 2014
Penalty
Initial $6,300 · Current $3,465 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:    a. On or about April 2, 2014, at the above addressed job site, employees who had been erecting and maintaining suspended swing stage scaffolds, were exposed to a fall hazard while working on fabricated frame scaffolds without means of conventional fall protection as the scaffolds lacked guardrails.    7  Instances: 7 three tier fabricated frame scaffolds about 5 feet wide, approximately 15 feet high that lacked guardrails on the upper level.    PLEASE NOTE THAT DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED.
Recent events (2)
  • — I (S) $3465
  • — Z (S) $6300

1926.451 G03 I

Serious Gravity 10 14 instances 16 exposed
Issued
Aug 5, 2014
Abate by
Aug 15, 2014
Penalty
Initial $6,300 · Current $3,465 Reduced
29 CFR 1926.451(g)(3)(i): Vertical lifelines were not fastened to a fixed safe point of anchorage, independent of the scaffold, and protected from sharp edges and abrasion:    a. On or about April 2, 2014, at the above addressed job site, employees who had been performing concrete restoration work, were exposed to fall hazards while performing concrete restoration work from suspended swing stage scaffolds while using vertical lifelines that had been tied to anchorages with knots.    14 Instances: 7 suspended scaffolds; each had two lifelines that had been secured to anchorages with knots.      PLEASE NOTE THAT DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED.
Recent events (2)
  • — I (S) $3465
  • — Z (S) $6300

View Paradigm Construction Group of South Florida, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339659880.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.