Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNIVERSAL REILLY CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UNIVERSAL REILLY CONSTRUCTION, INC. in 3301 S. KIRKMAN ROAD BLDG. #10, ORLANDO, FL 32801 (NAICS 238130). OSHA activity number 339660227.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Universal Reilly Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Universal Reilly Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3301 S. KIRKMAN ROAD BLDG. #10
City
ORLANDO
State
FL
ZIP
32801
Mailing
408 W. PEARL STREET, MINNEOLA, FL 34715
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.451 B01 I

Serious Gravity 10 1 instance 3 exposed
Issued
May 8, 2014
Penalty
Initial $2,520 · Current $1,600 Reduced
29 CFR 1926.451(b)(1)(i):   Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary.    (a) The supported scaffold erected at building #10 was not fully planked where spaces 18 inches wide were present on the second and third levels exposing the employees to a 15-foot fall hazard on or about April 1, 2014.
Recent events (2)
  • — I (S) $1600
  • — Z (S) $2520

1926.451 E06 I

Serious Gravity 10 1 instance 2 exposed
Issued
May 8, 2014
Penalty
Initial $2,800 · Current $1,740 Reduced
29 CFR 1926.451(e)(6)(i):   Integral prefabricated scaffold access frames were not specifically designed or constructed for use as ladder rungs:    (a).  At building #10 the erected three stories high supporting scaffold's end frames which were not designed for ladder access, were being used for access and egress to the second and third scaffold levels on or about April 1, 2014 .
Recent events (2)
  • — I (S) $1740
  • — Z (S) $2800

1926.1053 B13

Serious Gravity 5 1 instance 2 exposed
Issued
May 8, 2014
Penalty
Initial $1,360 · Current $0 Reduced
29 CFR 1926.1053(b)(13):   The top or top step of a stepladder was used as a step:    (a) At Building #10 of the Reserve Apartment Complex where exterior renovation was being done, the top cap and top step of the stepladder was used to gain access onto the scaffold, on or about April 1, 2014.