ORLANDO, FL —
OSHA Inspection: UNIVERSAL REILLY CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of UNIVERSAL REILLY CONSTRUCTION, INC. in 3301 S. KIRKMAN ROAD BLDG. #10, ORLANDO, FL 32801 (NAICS 238130). OSHA activity number 339660227.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNIVERSAL REILLY CONSTRUCTION, INC.
- Site address
- 3301 S. KIRKMAN ROAD BLDG. #10
- City
- ORLANDO
- State
- FL
- ZIP
- 32801
- Mailing
- 408 W. PEARL STREET, MINNEOLA, FL 34715
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B01 I
- Issued
- May 8, 2014
- Penalty
- Initial $2,520 · Current $1,600 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. (a) The supported scaffold erected at building #10 was not fully planked where spaces 18 inches wide were present on the second and third levels exposing the employees to a 15-foot fall hazard on or about April 1, 2014.
Recent events (2)
- — I (S) $1600
- — Z (S) $2520
1926.451 E06 I
- Issued
- May 8, 2014
- Penalty
- Initial $2,800 · Current $1,740 Reduced
General-duty citation text
29 CFR 1926.451(e)(6)(i): Integral prefabricated scaffold access frames were not specifically designed or constructed for use as ladder rungs: (a). At building #10 the erected three stories high supporting scaffold's end frames which were not designed for ladder access, were being used for access and egress to the second and third scaffold levels on or about April 1, 2014 .
Recent events (2)
- — I (S) $1740
- — Z (S) $2800
1926.1053 B13
- Issued
- May 8, 2014
- Penalty
- Initial $1,360 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: (a) At Building #10 of the Reserve Apartment Complex where exterior renovation was being done, the top cap and top step of the stepladder was used to gain access onto the scaffold, on or about April 1, 2014.