Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QUALITY PLUS SERVICES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of QUALITY PLUS SERVICES, INC. in HARRISON AVE & 6TH STREET FIRST BAPTIST CHURCH, PANAMA CITY, FL 32405 (NAICS 236220). OSHA activity number 339661076.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quality Plus Services, INC. — free Get an email when a new federal OSHA severe-injury report for Quality Plus Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
HARRISON AVE & 6TH STREET FIRST BAPTIST CHURCH
City
PANAMA CITY
State
FL
ZIP
32405
Mailing
7111 BAYOU GEORGE DRIVE, PANAMA CITY, FL 32405
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
6
Ownership type
A

5 citations on file for this inspection.

1926.451 F03

Serious Gravity 10 1 instance 6 exposed
Issued
Aug 8, 2014
Penalty
Initial $7,000 · Current $7,000
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:  a. On or about March 26, 2014, employees, at the Harrison Ave & 6th Street job site, were repairing a bell tower while working from an  80-foot tubular welded frame scaffold system.  The scaffolding contractor completed assembly of the scaffold system on March 6, 2014, and the employer did not perform daily inspections of the scaffold and scaffold components by a competent person before each work shift.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1926.451 F06

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 8, 2014
Penalty
Initial $7,000 · Current $7,000
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6):  a. On or about March 25, 2014, employees, working on the  80-foot tubular welded frame scaffolding system, were moving an aluminum 24-inch wide by 20 foot long pick board to a new level when the pick board came into contact with 7,200 kV power lines, exposing the employees to electrocution and severe burns.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1926.451 F07

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 8, 2014
Abate by
Sep 4, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration; Such activities were not performed only by experienced and trained employees selected for such work by the competent person:   a.  On or about March 25, 2014, employees, working on the 80-foot tubular welded frame scaffolding system, were moving an aluminum 24-inch wide by 20 foot long pick board to a new level when the pick board came into contact with 7,200 kV power lines, exposing the employees to electrocution and severe burns.  The employer did not have a qualified competent person supervising or directing the employees while the employees were moving the scaffold components.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 8, 2014
Abate by
Sep 4, 2014
Penalty
Initial $7,000 · Current $7,000
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:  a. On or about March 25, 2014, the employer did not have each employee performing work from an 80-foot tubular welded frame scaffold system trained to recognize the hazards, such as electrical hazards, associated with the scaffold being used, to understand the procedures to control or minimize those hazards to include the information as outlined in 29 CFR 1926.454(a)(1) through (5).
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1926.454 B

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 8, 2014
Abate by
Sep 4, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question:  a. On or about March 25, 2014, the employer did not have each employee involved in moving the scaffold system trained by a competent person to recognize any hazards associated with the work.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Quality Plus Services, INC.'s full OSHA safety record →