Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: KAVAC, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KAVAC, LLC in 1707-1713 MCGOWEN ST., HOUSTON, TX 77004 (NAICS 236116). OSHA activity number 339662033.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kavac, LLC for free Get an email when a new federal OSHA severe-injury report for Kavac, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
KAVAC, LLC
Site address
1707-1713 MCGOWEN ST.
City
HOUSTON
State
TX
ZIP
77004
Mailing
619 RUTLAND #B, HOUSTON, TX 77077
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
8
Ownership type
Private (A)

6 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 3 instances 3 exposed
Issued
Apr 23, 2014
Abate by
May 1, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.20(b)(2): The employer did not ensure that frequent and regular inspections of the job sites, materials, and equipment were conducted by a competent person:  (a) at the jobsite, frequent and regular inspections were not performed.
Recent events (1)
  • · Z (S) $2000

1926.150 C01 VI

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 23, 2014
Abate by
Apr 25, 2014
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas were being used on the jobsite:  (a) at the jobsite, first floor roof, fire extinguishers were not available when torching the roofing materials with propane.
Recent events (1)
  • · Z (S) $1600

1926.405 B02

Serious Gravity 5 1 instance 8 exposed
Issued
Apr 23, 2014
Abate by
Apr 25, 2014
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings were not provided with covers:  (a) at the jobsite, temporary power pole, a 120-volt outlet lacked a cover.
Recent events (1)
  • · Z (S) $1600

1926.405 D

Serious Gravity 5 1 instance 8 exposed
Issued
Apr 23, 2014
Abate by
Apr 25, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.405(d): A panelboard was not dead front:  (a) at the jobsite, temporary power pole, the breaker box did not have a dead front. The outer cover was also missing.
Recent events (1)
  • · Z (S) $2000

1926.501 B10

Serious Gravity 1 2 instances 2 exposed
Issued
Apr 23, 2014
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on flat roofs with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, warning line system, or a safety monitoring system:  (a) at the jobsite, employees torching the roofing materials on the first floor roof, more than six feet above the ground, were not protected by any type of a fall protection system.
Recent events (1)
  • · Z (S) $1200

1926.404 B01 I

Other-than-serious 2 instances 8 exposed
Issued
Apr 23, 2014
Abate by
Apr 25, 2014
Penalty
Initial $400 · Current $400
29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:  (a) at the job-site, on the temporary power pole, extension cords and equipment were energized by 110 VAC and 220 VAC outlets that were not protected by GFCIs.
Recent events (1)
  • · Z (O) $400

View Kavac, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339662033.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.