WHEELING, IL —
OSHA Inspection: C R PLASTICS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of C R PLASTICS, INC. in 851 SETON COURT #1C, WHEELING, IL 60090 (NAICS 326199). OSHA activity number 339662843.
Where did this inspection happen?
- Establishment
- C R PLASTICS, INC.
- Site address
- 851 SETON COURT #1C
- City
- WHEELING
- State
- IL
- ZIP
- 60090
- Mailing
- 851 SETON COURT #1C, WHEELING, IL 60090
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 11
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.133 A01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) Production Area- The employer failed to require the use of eye and face protection, such safety glasses and a face shield, for employees that were exposed to molten plastic and flying particles during equipment operation and set-up. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1200
- — Z (S) $2800
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Production Area- The employer failed to establish a Lockout Tagout Program consisting of an energy control procedures, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on machines such as the Extruders or equipment where the unexpected energization, startup or release of stored energy could occur and cause injury. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.305 G02 III
- Issued
- Penalty
- Initial $1020.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) Production Area- The employer failed to ensure that flexible cords, such as the plug for the Oil Pump on JSW J385E Injection Molding Machine, Serial #292012043, were supplied with strain relief to prevent pull from being transferred to joints. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $800
- — Z (S) $1020
1910.22 D01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. a) Production Area- The employer did not provide markings or capacity plate designating the load capacity for storage areas such as the storage area above the offices in the Production Area. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 326199)
ERIE, PA—2026-07-14
CAPLUGS, LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
PETALUMA, CA—2026-07-10
LABCON NORTH AMERICA
KEEWATIN, MN—2026-07-09
111565 - TACKLE TAMER PRODUCTS INC
EAST FLAT ROCK, NC—2026-07-09
161517 - ELKAMET, INC.
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339662843.