BOONTON, NJ —
OSHA Inspection: WORLDWIDE INDUSTRIES CORP.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of WORLDWIDE INDUSTRIES CORP. in 795 GREEN ST, BOONTON, NJ 07005 (NAICS 238990). OSHA activity number 339663957.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WORLDWIDE INDUSTRIES CORP.
- Site address
- 795 GREEN ST
- City
- BOONTON
- State
- NJ
- ZIP
- 07005
- Mailing
- 470 MITCHELL HILL RD, BUTLER, PA 16003
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 2
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.134 C01
- Issued
- Jun 27, 2014
- Abate by
- Oct 1, 2014
- Penalty
- Initial $2,640 · Current $1,388 Reduced
General-duty citation text
29 CFR 1910.134(c)(1) as referenced by 29 CFR 1926.103: A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) Worksite located at 795 Green St, Boonton, NJ The employer did not implement the company's written respiratory protection programs for employees required to wear half mask, negative pressure respirators such as, but not limited to, 3M. The employer did not provide medical evaluations, fit tests, and respirators were worn with facial hair. Violation occurred on or about 04/02/14.
Recent events (2)
- — I (S) $1388
- — Z (S) $2640
1910.134 E01
- Issued
- Jun 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1) as referenced by 29 CFR 1926.103: The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Worksite located at 795 Green St, Boonton, NJ The employer did not provide a medical evaluation for employees required to wear respirators such as, but not limited to, 3M half mask, negative pressure respirators. Violation occurred on or about 04/25/14.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F02
- Issued
- Jun 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2) as referenced by 29 CFR 1926.103: Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: a) Worksite located at 795 Green St, Boonton, NJ The employer did not provide fit tests to employees required to wear respirators such as, but not limited to, 3M half mask, negative pressure respirators. Violation occurred on 04/02/14.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 G01 I A
- Issued
- Jun 27, 2014
- Abate by
- Jul 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: a) Worksite located at 795 Green St, Boonton, NJ Employees who wore half mask respirators wore them with facial hair that interfered with the sealing surface of the face piece. Violation observed on or about 04/02/14.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 I01 II
- Issued
- Jun 27, 2014
- Abate by
- Jul 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(i)(1)(ii): Breathing air did not meet requirements for Grade D breathing air as described in the ANSI/Compressed Gas Association Commodity Specification G-7.1-1989: a) Worksite located at 795 Green St, Boonton, NJ An employee using an Ingersoll Rand HP915WCU compressor for breathing air did not meet the requirements for Grade D breathing air. Violation occurred on or about 04/02/14.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 I07
- Issued
- Jun 27, 2014
- Abate by
- Jul 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(i)(7) as referenced by 29 CFR 1926.103: Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both: a) Worksite located at 795 Green St, Boonton, NJ The Ingersoll Rand HP915WCU compressor used for breathing air did not have a high temperature alarm and/or carbon monoxide alarm. Violation observed on or about 04/02/14.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.52 D01
- Issued
- Jun 27, 2014
- Abate by
- Oct 1, 2014
- Penalty
- Initial $2,200 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.52(d)(1): In all cases where the sound levels exceeded the values shown in Table D-2 of 29 CFR 1926.52, a continuing, effective hearing conservation program was not administered: a) Worksite located at 795 Green St, Boonton, NJ An employee performing abrasive blasting was exposed to continuous noise levels at 786% of the permissible daily noise exposure (8 hour Time Weighted Average sound level of 90 dBA) which is 7.86 times the allowable exposure limit. The action level (AL) is 85 dBA. The equivalent sound level of the measured dose is 104.9 dBA. Sampling was performed for 350 minutes on 04/12/14, with the unsampled portion of time considered to represent zero for the exposure calculation. The employer did not conduct monitoring, provide audiograms or training.
Recent events (2)
- — I (S) $2000
- — Z (S) $2200
1926.302 B10
- Issued
- Jun 27, 2014
- Abate by
- Jul 17, 2014
- Penalty
- Initial $1,320 · Current $0 Reduced
General-duty citation text
29 CFR 1926.302(b)(10): Abrasive blast cleaning nozzles were not equipped with an operating valve which must be held open manually: a) Worksite at 795 Green St, Boonton, NJ The abrasive blast cleaning nozzle did not have an operating valve that must be held open manually. In the event the employee dropped the nozzle, it would stay open with the blasting media striking the employee. Violation observed on or about 04/12/14.
Recent events (2)
- — I (S) $0
- — Z (S) $1320
More inspections at Worldwide Industries Corp.