COLORADO SPRINGS, CO —
OSHA Inspection: 7TH FLOOR LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of 7TH FLOOR LLC in 1420 AVIATION WAY, COLORADO SPRINGS, CO 80916 (NAICS 339999). OSHA activity number 339664955.
Where did this inspection happen?
- Establishment
- 7TH FLOOR LLC
- Site address
- 1420 AVIATION WAY
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80916
- Mailing
- 1420 AVIATION WAY, COLORADO SPRINGS, CO 80916
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339999
- Employees
- 28
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- May 5, 2014
- Abate by
- Jun 20, 2014
- Penalty
- Initial $2,100 · Current $1,800 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a) On or about March 12, 2014, and at times prior, employees were exposed to falls because the employer did correctly use the mobile ladder stand that was used to access the mezzanine storage level above the offices. Employees placed the mobile ladder parallel to the wall and exited it from the side, going under rails to step onto the upper floor.
Recent events (3)
- — F (S) $1800
- — C (S) $2100
- — Z (S) $2100
1910.24 B
- Issued
- May 5, 2014
- Abate by
- Jun 20, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.24(b): Fixed stairs were not provided for access from one structure level to another where operations necessitated regular travel between levels, and for access to operating platforms at any equipment which requires attention routinely during operations: a) On or about March 12, 2014, and at times prior, employees were exposed to falls because the employer did not provide fixed stairs that would allow safe access to the mezzanine storage level above the offices. Employees routinely accessed this level to store and retrieve packaging materials by incorrectly using a portable staircase.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.23 C01
- Issued
- May 5, 2014
- Penalty
- Initial $1,785 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: a) On or about March 12, 2014, and at times prior, employees were exposed to fall hazards of greater than 4 feet when they worked on and around the storage area above the offices in the main shop because this level was not equipped with standard railings. A top rail had been constructed, but the rail system was missing a standard mid rail.
Recent events (3)
- — F (S) $1530
- — C (S) $1785
- — Z (S) $1785
1910.151 C
- Issued
- May 5, 2014
- Penalty
- Initial $1,785 · Current $1,585 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) On or about March 12, 2014, and at times prior, employees were exposed to eye injuries while they used corrosive chemicals such as Lysol toilet cleaner to remove baked-on decals from vaporizers without access to a suitable eyewash facility in the immediate area.
Recent events (3)
- — F (S) $1585
- — C (S) $1785
- — Z (S) $1785
1910.1200 E01
- Issued
- May 5, 2014
- Abate by
- May 9, 2014
- Penalty
- Initial $2,100 · Current $1,585 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On or about March 12, 2014, and at times prior, the employer failed to fully develop and implement a hazard communication program in order to inform employees of the health hazards associated with the chemicals used in the production area.
Recent events (3)
- — F (S) $1585
- — C (S) $2100
- — Z (S) $2100
1910.22 D01
- Issued
- May 5, 2014
- Abate by
- May 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed to the building: a) On or about March 12, 2014, and at times prior, employees were exposed to struck-by or crushed-by hazards while they worked under and around the storage area above the shop offices which housed packaging supplies. The employer had not posted the load rating for the roof structure.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.132 D02
- Issued
- May 5, 2014
- Abate by
- May 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: a) On or about March 12, 2014, and at times prior, the employer did not verify, through written certification, that a hazard assessment of the workplace had been performed to determine the type of personal protective equipment necessary to protect employees from such hazards as chemicals, flying chips and particles, power tools, and noise.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.134 C02 II
- Issued
- May 5, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: On or about March 12, 2014, and at times prior, the employer did not establish a written respiratory protection program and provide training to employees who voluntarily used elastomeric half-face respirators. to protect themselves from asbestos fibers while cutting pipe which contained asbestos. At least one employee used this type of respirator without being provided a medical evaluation and basic training in respirator use, cleaning, storage and maintenance which ensured that the use of the respirator itself did not present a health hazard.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 339999)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339664955.