Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GLYNN ELECTRIC, INCORPORATED

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of GLYNN ELECTRIC, INCORPORATED in 27 DRY DOCK AVE, BOSTON, MA 02114 (NAICS 238210). OSHA activity number 339669129.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Glynn Electric, Incorporated — free Get an email when a new federal OSHA severe-injury report for Glynn Electric, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
27 DRY DOCK AVE
City
BOSTON
State
MA
ZIP
02114
Mailing
11 RESNICK ROAD, PLYMOUTH, MA 02360
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
7
Ownership type
A

2 citations on file for this inspection.

1910.332 B01

Serious Gravity 10 2 instances 7 exposed
Issued
Aug 26, 2014
Abate by
Oct 16, 2014
Penalty
Initial $4,900 · Current $4,900
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:     LOCATION:  27 Drydock Ave., Black Falcon Pier, Boston MA:     Employees who preform electrical work and testing on energized equipment and systems were not effectively trained in implementing electrical safety-related work practices for tasks, including but not limited to changing lighting ballasts.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $4900

1910.333 A01

Serious Gravity 10 1 instance 6 exposed
Issued
Aug 26, 2014
Abate by
Oct 16, 2014
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.333(a)(1): Live parts to which an employee was exposed were not deenergized before the employee worked on or near them:    LOCATION: BLACK FALCON TERMINAL, BOSTON MA:        An employee was shocked and burned when contact was made with live parts while testing and changing a lighting fixture ballast where the current had not been de-energized.