ASHLAND, WI ·
OSHA Inspection: ASHLAND MAT, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ASHLAND MAT, LLC in 3610 ELLIS AVE, ASHLAND, WI 54806 (NAICS 321113). OSHA activity number 339669368.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ASHLAND MAT, LLC
- Site address
- 3610 ELLIS AVE
- City
- ASHLAND
- State
- WI
- ZIP
- 54806
- Mailing
- P.O. BOX 682, ASHLAND, WI 54806
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 12
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.23 A08
- Issued
- Aug 4, 2014
- Abate by
- Sep 2, 2014
- Penalty
- Initial $2,400 · Current $1,560 Reduced
General-duty citation text
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded: (a) Headsaw deck; An exposed floor hole was not protected by a guardrail system or floor hole cover. The floor hole was approximately 35-1/2 inches long by 12 inches wide.
Recent events (2)
- · I (S) $1560
- · Z (S) $2400
1910.147 C01
- Issued
- Aug 4, 2014
- Abate by
- Sep 23, 2014
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) Throughout the facility; An energy control program (Lockout-Tagout) was not developed or implemented for equipment with multiple sources of energy such as, but not limited to; debarker, headsaw, log carriage, deck saw, and band resaw.
Recent events (2)
- · I (S) $1820
- · Z (S) $2800
1910.147 D04 I
- Issued
- Aug 4, 2014
- Abate by
- Sep 23, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Production area; Energy isolation devices were not used during jam clearing and cleaning operations on equipment such as, but not limited to; debarker, headsaw, log carriage, deck saw, band resaw, and conveying systems.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.265 E01 V
- Issued
- Aug 4, 2014
- Abate by
- Aug 18, 2014
- Penalty
- Initial $1,600 · Current $1,040 Reduced
General-duty citation text
29 CFR 1910.265(e)(1)(v): A barrier was not provided to prevent employees from entering the space necessary for travel of the carriage and warning signs were not posted at possible entry points to log carriage areas: (a) Sawmill, log carriage for head saw; Barriers were not provided around the head saw carriage to prevent access. (b) Sawmill, log carriage for head saw; Signage was not provided around the head saw carriage to warn against hazards.
Recent events (2)
- · I (S) $1040
- · Z (S) $1600
1910.265 C18 I
- Issued
- Aug 4, 2014
- Abate by
- Sep 23, 2014
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.265(c)(18)(i): Construction, operation, and maintenance of conveyors was not conducted in accordance with American National Standard B20.1-1957, which is incorporated by reference as specified in Sec. 1910.6: (a) Production area; In-running nip-points of a chain(s) and sprocket(s) on conveyor transfer and discharge points were not guarded (Reference: American National Standard B20.1-1957, Section 602). i. Resaw station, transfer conveyor; In-running nip-points of a chain and sprocket on a powered chain conveyor were not guarded. ii. Cant deck; In-running nip-point(s) between a chain and sprockets were not guarded. (b) Production area; Crossover(s) or passageway(s) were not provided for chain and vibrating style conveyors located within 7 feet of the floor or walkway surface (Reference: American National Standard B20.1-1957, Section 705.a). i. Resaw conveyor loop; A crossover was not provided for the chain conveyor systems. ii. Between deck saw and cant deck; A crossover was not provided for the vibrating conveyor system.
Recent events (2)
- · I (S) $1820
- · Z (S) $2800
1910.179 J03
- Issued
- Aug 4, 2014
- Abate by
- Sep 23, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months: (a) Production facility; A comprehensive crane inspection was not conducted within the last 12 months.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 321113)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339669368.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.