Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MCLEOD EXPRESS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MCLEOD EXPRESS, LLC in 5002 CUNDIFF CT, DECATUR, IL 62526 (NAICS 484110). OSHA activity number 339669558.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mcleod Express, LLC — free Get an email when a new federal OSHA severe-injury report for Mcleod Express, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
MCLEOD EXPRESS, LLC
Site address
5002 CUNDIFF CT
City
DECATUR
State
IL
ZIP
62526
Mailing
5002 CUNDIFF CT, DECATUR, IL 62526
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484110
Employees
63
Ownership type
A

12 citations on file for this inspection.

1910.133 A03

Other-than-serious 1 instance 1 exposed
Issued
Sep 9, 2014
Abate by
Sep 15, 2014
Penalty
Initial $3,000 · Current $0 Reduced
29 CFR 1910.133(a)(3):     The employer did not ensure that each affected employee who wears prescription lenses while engaged in operations that involve eye hazards wore eye protection that incorporated the prescription in its design, or wore eye protection that could be worn over the prescription lenses without disturbing the proper position of the prescription lenses or the protective lenses:    An employee was exposed to eye injuries while performing service and maintenance activities on the trucks and was not provided appropriate eye protection.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3000

1910.151 C

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 9, 2014
Abate by
Oct 27, 2014
Penalty
Initial $5,000 · Current $3,500 Reduced
29 CFR 1910.151(c):     Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    An employee working in the Wash Bay was exposed to eye and skin injuries while working around and with hazardous chemicals, such as, but not limited to, Aluminum Clean and Bright, and an emergency eyewash and shower were not immediately adjacent to the hazard.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5000

1910.178 L01 II

Other-than-serious 1 instance 2 exposed
Issued
Sep 9, 2014
Abate by
Sep 15, 2014
Penalty
Initial $6,000 · Current $700 Reduced
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck:     The employer had not provided training to each operator on the safe operation of the Caterpillar 50 Forklift.
Recent events (2)
  • — I (O) $700
  • — Z (S) $6000

1910.178 L06

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 9, 2014
Abate by
Sep 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6):   The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):   The employer did not certify that each operator of the powered industrial truck had been trained and evaluated in the safe operation of the Caterpillar 50 Forklift.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A05

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 9, 2014
Abate by
Sep 15, 2014
Penalty
Initial $5,000 · Current $3,500 Reduced
29 CFR 1910.212(a)(5):     Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level:     An employee, working in the Truck Shop, was exposed to amputation hazards because the fan blades on the homemade fan was less than seven feet off the floor and was not guarded.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5000

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 9, 2014
Abate by
Sep 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1):   Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):   An employee, working in the Truck Shop, was exposed to amputation hazards because the pulley located on the homemade fan, was less than seven feet off the floor and was not adequately guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 E04

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 9, 2014
Abate by
Sep 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(4):   Vertical belts running over a lower pulley more than seven (7) feet above floor or platform shall be guarded at the bottom in the same manner as horizontal overhead belts, if conditions are as stated in paragraphs (e)(2)(ii) (a) and (c) of this section:  An employee, working in the Truck Bay, was exposed to amputation hazards because the belt located in the homemade fan, was less than seven feet off the floor and was not adequately enclosed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 4 instances 3 exposed
Issued
Sep 9, 2014
Abate by
Sep 15, 2014
Penalty
Initial $4,000 · Current $2,800 Reduced
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:     Employees working in the Truck Shop were exposed to electrical hazards:     a.    a 6-outlet wall mount surge protector was lying unsecured on the floor in Bay 3 East and was not being used for its intended purpose.      b.    a relocatable power tap located in Bay 3 East was plugged into a 6-outlet wall mount surge protector which was plugged into an extension cord which was plugged into the wall outlet.  The relocatable power tap and the 6-outlet wall mount surge protector were not being used for their intended purpose.     c.    the water cooler and the vending machine located in the Vending Area located in Bay 1 West were plugged in to a relocatable power tap which was daisy chained into another relocatable power tap which was plugged into the wall outlet.  The relocatable power taps were not being used for their intended purpose.      d.    a refrigerator located in the Center of Bay 1 was plugged into an extension cord which was plugged into a relocatable power tap.  The relocatable power tap was not being used for its intended purpose.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $4000

1910.304 G05

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 9, 2014
Abate by
Sep 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5):   The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:   Employees were exposed to electrical hazards because the water cooler and the vending machine located in the Vending Area Bay 1 West were plugged into a relocatable power tap which was daisy chained into another relocatable power tap that did not possess the necessary ground prong.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 4 instances 3 exposed
Issued
Sep 9, 2014
Abate by
Sep 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):   Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   Employees working in the Truck Shop were exposed to electrical hazards:   a.  a 6-outlet wall mount surge protector was lying unsecured on the floor in Bay 3 East and was being used for a substitute of fixed wiring of the structure.     b.  a relocatable power tap located in Bay 3 East was plugged into a 6-outlet wall mount surge protector which was plugged into an extension cord which was plugged into the wall outlet.  The relocatable power tap and the 6-outlet wall mount surge protector were being used foe a substitute of fixed wiring of the structure.   c.  the water cooler and the vending machine located in the Vending Area located in Bay 1 West were plugged into a relocatable power tap which was daisy chained into another relocatable power tap which was plugged into the wall outlet.  The relocatable power taps were being used for a substitute of fixed wiring of a structure.     d.  a refrigerator located in the Center of Bay 1 was plugged into an extension cord which was plugged into an outlet.  The extension cord was being used as a substitute of fixed wiring of the structure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV B

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 9, 2014
Abate by
Sep 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B):   Flexible cords and cables were run through holes in walls, ceilings or floors:  Employees were exposed to electrical hazards because an electrical cord was run through the wall of the storage room located in the Truck Shop to the refrigerator located in the Center of Bay 1.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F06 I

Other-than-serious 1 instance 1 exposed
Issued
Sep 9, 2014
Abate by
Sep 15, 2014
Penalty
Initial $3,000 · Current $0 Reduced
29 CFR 1910.1200(f)(6)(i):     Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v):     An employee working in the Truck Shop in Bay 3 East was exposed to hazardous chemicals, including but not limited to washer fluid, and the contents were not marked with the appropriate chemicals identity and hazard warning.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3000

View Mcleod Express, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339669558.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.