Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MASON ROAD SHEET METAL

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MASON ROAD SHEET METAL in 6450 CLARA ROAD #190, HOUSTON, TX 77041 (NAICS 332322). OSHA activity number 339670390.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mason Road Sheet Metal — free Get an email when a new federal OSHA severe-injury report for Mason Road Sheet Metal is published. One employer, no account, unsubscribe in one click.
Site address
6450 CLARA ROAD #190
City
HOUSTON
State
TX
ZIP
77041
Mailing
6450 CLARA ROAD #190, HOUSTON, TX 77041
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
102
Ownership type
A

3 citations on file for this inspection.

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 3, 2014
Abate by
Jun 18, 2014
Penalty
Initial $3,600 · Current $2,160 Reduced
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work.  The employer does not ensure that work rests are used to support offhand grinding work.  This violation was observed on or about April 10, 2014, in the Spiral Shop area where employees were exposed to caught-in hazards when operating a Dayton bench grinder that did not have a work rest.   Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that work rests are installed on all grinding equipment used for offhand grinding work.
Recent events (2)
  • — I (S) $2160
  • — Z (S) $3600

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 3, 2014
Abate by
Jun 18, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch.     The employer does not ensure that the distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top did not exceed one fourth inch. This violation occurred on or about April 10, 2014, in the Spiral Shop where employees were exposed to struck-by hazards when operating a Dayton bench grinder without a tongue guard and the distance between the abrasive wheel periphery(s) and the safety guard peripheral member at the top exceeded one fourth inch.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that Dayton bench grinder is used so that the distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top does not exceed one fourth inch.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 3, 2014
Abate by
Jun 18, 2014
Penalty
Initial $3,600 · Current $2,160 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.   The employer does not ensure that unused openings in boxes, cabinets, or fittings are effectively closed. This violation was observed on or about April 10, 2014, in the Welding Shop, in an electrical panel #LN where employees are exposed to electrical hazards when accessing the breakers without the unused openings being effectively closed.   Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all unused openings  in boxes, cabinets, or fittings are effectively closed.
Recent events (2)
  • — I (S) $2160
  • — Z (S) $3600