Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JMC STEEL GROUP, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JMC STEEL GROUP, INC. in 6340 AL HIGHWAY 5, THOMASVILLE, AL 36762 (NAICS 331210). OSHA activity number 339670564.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JMC Steel Group, INC. — free Get an email when a new federal OSHA severe-injury report for JMC Steel Group, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6340 AL HIGHWAY 5
City
THOMASVILLE
State
AL
ZIP
36762
Mailing
6340 AL HIGHWAY 5, THOMASVILLE, AL 36762
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331210
Employees
200
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Aug 4, 2014
Abate by
Aug 14, 2014
Penalty
Initial $3,375 · Current $0 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to burns and other injuries related to accidental contact with hot surfaces:   a)  Casing Heat Treatment Lines: On or about April 9, 2014 and at times prior thereto, the employer did not ensure guarding or another equivalent method was provided to prevent accidental contact with the steel pipes being heated up to 1670 degrees Fahrenheit.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3375

1910.219 F03

Other-than-serious 2 instances 3 exposed
Issued
Aug 4, 2014
Penalty
Initial $2,869 · Current $7,000
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed:       b) CNC 3 Waste: On or about April 9, 2014 and at times prior thereto, the employer did not ensure machine guarding or another effective method was used which exposed employees to amputations and other injuries associated with ingoing nip points..
Recent events (2)
  • — I (O) $7000
  • — Z (S) $2869

1910.303 B06

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 4, 2014
Penalty
Initial $1,721 · Current $1,721
29 CFR 1910.303(b)(6): Conductors located in wet or damp locations were not identified for that environment:  a) Between Tubing Quench and MCC Room: On or about April 9, 2014 and at times prior thereto, the employer did not ensure a 2 receptacle outlet had ground fault circuit interrupter (GFCI) protection which exposed employees to electric shock hazards.